Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

Winefilter II MF 5043 Hollow Fiber Crossflow

Engineering summary from PDF text extraction for Winefilter II MF 5043 Hollow Fiber Crossflow. Verify every value with the OEM datasheet.

Summary

Product identification

These are Hollow Fiber Crossflow Microfiltration Cartridges for Wine Filtration.

  • Membrane Type: Microfiltration
  • Pore Size: Microporous
  • Housing Construction: Polysulfone shell and end caps
  • Regulatory Status: Conforms to FDA regulations (CFR Title 21)
  • Storage Solution: Glycerin

Product Specifications:

Part NumberModelActive Membrane Area ft² (m²)Fiber Inside Diameter mil (mm)
0720263WINEFILTER MF 504368 (6.3)52 (1.3)
0720264WINEFILTER MF 506095 (8.8)52 (1.3)

Operating limits

  • Recommended Inlet Pressure: 20-30 psi (1.4-2.1 bar)
  • Maximum Transmembrane Pressure: 25 psi (1.7 bar)
  • Maximum Feed Side Pressure Drop: 25 psi (1.7 bar)
  • Maximum Backflush Pressure: 20 psi (1.4 bar)
  • Maximum Operating Temperature: 104°F (40°C) @ pH 6
  • Maximum Cleaning Temperature: 122°F (50°C)
  • Allowable pH (Cleaning): 1.5 – 13.0 @ 104°F (40°C)

Feed water

For cartridge installation, use only water or glycerin to lubricate seals. Avoid petroleum or vegetable-based oils/solvents as they may damage the cartridge and void the warranty.

Exposure to chemical oxidants like peracetic acid blends, hydrogen peroxide, and sodium hypochlorite may be necessary for cleaning and sanitization. Consult KMS for recommended addition rates, frequency of use, and tolerance.

Potassium metabisulfite (without catalyst such as cobalt) is the preferred chemical to eliminate residual chlorine or similar oxidizers prior to processing the feed stream.

Mechanical / hydraulic

Nominal Dimensions:

ModelA inch (mm)B inch (mm)C inch (mm)D inch (mm)Permeate ConnectionProcess Connection
WINEFILTER MF 504343 (1,092)5.0 (127)38⅝ (981)6.0 (152)1½” NPSM6” NPSM
WINEFILTER MF 506060 (1,524)5.0 (127)55⅝ (1,413)6.0 (152)1½” NPSM6” NPSM