Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

TFC

Engineering summary from PDF text extraction for TFC. Verify every value with the OEM datasheet.

Summary

Product identification

Fluid Systems® TFC®-SS 8” elements are high rejection, seawater reverse osmosis (RO) membrane elements.

  • Membrane Chemistry: Proprietary TFC polyamide
  • Membrane Type: TFC-SS membrane
  • Construction: Spiral wound with fiberglass outerwrap
  • Applications: Seawater desalination, high rejection RO membrane
  • Options: 40” (1,016 mm) and 60” (1,524 mm) Magnum® length, standard or high area construction
ModelPermeate Flow gpd (m³/d)Chloride Rejection percentMembrane Area ft² (m²)
2822 SS-3005,000 (18.9)99.6300 (27.9)
2822 SS-3606,000 (22.7)99.6360 (33.4)
2832 SS-465 Magnum®7,750 (29.3)99.6465 (43.2)
2832 SS-540 Magnum®9,000 (34.3)99.6540 (50.2)

Note: Individual element permeate flows may vary +/-15% from the values shown. Minimum rejection is 99.3% at specified test conditions.

Operating limits

  • Typical Operating Pressure: 750–950 psi (5,175–6,555 kPa)
  • Maximum Operating Pressure: 1,200 psi (8,275 kPa)
  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Cleaning Temperature: 113°F (45°C)
  • Allowable pH (continuous operation): 4–11
  • Allowable pH (short term cleaning): 2.5–11
  • Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition).
  • Recovery: Site and application specific. Single element recovery is approximately 7% for 40” (1,016 mm) long elements and 11% for 60” (1,524 mm) long elements.

Feed water

  • Maximum Continuous Free Chlorine: <0.1 mg/l
  • Maximum Feed Turbidity: 1 NTU
  • Maximum Feed SDI (15 minute test): 5.0
  • Chlorine Tolerance: Intentional exposure to free chlorine or other oxidizing agents is not recommended. TFC-SS membrane has a free chlorine tolerance of approximately 1,000 ppm-hours based on testing at 77°F (25°C), pH 8. This tolerance may be significantly reduced if catalyzing metals such as iron are present or if the pH and/or temperature are different. Sodium metabisulfite (without catalysts such as cobalt) is the preferred reducing agent.
  • Chloramine Tolerance: Approximately 60,000 ppm-hours in the absence of free chlorine based on testing at 77°F (25°C), pH 8.
  • Cationic Polymers and Surfactants: Not recommended; TFC-SS membrane may be irreversibly fouled if exposed to cationic (positively charged) polymers or surfactants.

Product water

  • Chloride Rejection (nominal): 99.6%
  • Minimum Rejection: 99.3%
  • Test Conditions: 32,800 mg/l NaCl solution (isosmotic to ASTM standard seawater) at 800 psi (5,520 kPa) applied pressure, 7% recovery (11% recovery for Magnum elements), 77°F (25°C) and pH 7.5.

Mechanical / hydraulic

  • Feed Spacer Thickness: 28/31 mil (0.7/0.8 mm)
  • Maximum Differential Pressure per Element:
    • 10 psi (69 kPa) for 40” (1,016 mm) long elements
    • 15 psi (104 kPa) for 60” (1,524 mm) long elements
  • Maximum Differential Pressure per Vessel: 60 psi (414 kPa)
ModelA (Length) inches (mm)B (Diameter) inches (mm)C (Permeate Tube ID) inches (mm)Weight lbs (kg)
2822 SS-30040 (1,016)8 (203.2)1.125 (28.6)40 (18)
2822 SS-36040 (1,016)8 (203.2)1.125 (28.6)49 (20)
2832 SS-465 Magnum®60 (1,524)8 (203.2)1.125 (28.6)58 (26)
2832 SS-540 Magnum®60 (1,524)8 (203.2)1.125 (28.6)60 (27)

Lubricants: For element loading, use only approved silicone lubricant, water, or glycerin to lubricate O-rings and brine seals. The use of petroleum-based lubricants or vegetable-based oils may damage the element and void the warranty.