Summary

Product identification

The FLUID SYSTEMS® TFC®- ULP® 4” ELEMENT is an ultra-low pressure reverse osmosis (RO) element.

  • Membrane Chemistry: Proprietary TFC® polyamide
  • Membrane Type: TFC®-ULP® membrane
  • Construction: Spiral wound element
  • Applications: Ultra low pressure applications for light industrial and potable water production
  • Options: Fiberglass overwrap or tape overwrap (-T)

Specifications

Part NumberModelPermeate Flow gpd (m³/d)Chloride Rejection percentActive Membrane Area ft² (m²)Feed Spacer mil (mm)
84820024040-ULP1,800 (6.8)98.6585 (7.9)28 (0.7)
84040084040-ULP-T1,800 (6.8)98.6585 (7.9)28 (0.7)

Test Conditions: 2,000 mg/l NaCl solution at 125 psi (860 kPa) applied pressure, 15% recovery, 77°F (25°C), and pH 7.5.

Performance Notes:

  • Individual element permeate flows may vary +20% / -15% from the nominal values shown.
  • Minimum chloride ion rejection is 97.5% under the specified test conditions.

Operating limits

  • Typical Operating Pressure: 100 - 175 psi (690 - 1,208 kPa)
  • Maximum Operating Pressure: 350 psi (2,400 kPa)
  • Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
  • Maximum Differential Pressure per Element: 10 psi (69 kPa)
  • Maximum Differential Pressure per Vessel: 60 psi (414 kPa) for FRP overwrap elements; 30 psi (207 kPa) for tapewrap elements.
  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Cleaning Temperature: 113°F (45°C)
  • Allowable pH – Continuous Operation: 4 - 11
  • Allowable pH – Short Term Cleaning: 2.5 - 11 (Limit exposure to extended pH range to 4 hours, once per month)
  • Maximum Continuous Free Chlorine: <0.1 mg/l
  • Free Chlorine Tolerance: Approximately 1,000 ppm-hours based on testing at 77°F (25°C), pH 8. This tolerance may be significantly reduced if catalyzing metals (e.g., iron) are present or if pH/temperature are different. Sodium metabisulfite is the preferred reducing agent.
  • Chloramine Tolerance: Approximately 60,000 ppm-hours in the absence of free chlorine based on testing at 77°F (25°C), pH 8.
  • Maximum Feed Turbidity: 1 NTU (Feedwater with turbidity greater than 0.2 NTU generally results in frequent cleanings).
  • Maximum Feed SDI (15 minute test): 5
  • Maximum Number of Tape Wrap Elements Per Vessel: 3
  • Recovery: Maximum recovery is site and application specific. Single element recovery is approximately 15% per element.
  • Cationic Polymers and Surfactants: Not recommended due to risk of irreversible fouling.
  • Lubricants: Only approved silicone lubricant, water, or glycerin should be used for O-rings and brine seals during element loading. Petroleum-based lubricants or vegetable-based oils may damage the element and void the warranty.

Mechanical / hydraulic

ModelA inches (mm)B inches (mm)C inches (mm)D inches (mm)Weight lbs (kg)InterconnectorO-ringBrine Seal
4040-ULP40 (1,016)4 (101.6)0.75 (19.0)1.0 (25.4)10 (4.5)003526700354580035702
4040-ULP-T40 (1,016)4 (101.6)0.75 (19.0)1.0 (25.4)10 (4.5)003526700354580035702