Datasheet summary
ROGA-HR8 / ROGA-8040-HR-325 / 8232 HR Magnum
Engineering summary from PDF text extraction for ROGA-HR8 / ROGA-8040-HR-325 / 8232 HR Magnum. Verify every value with the OEM datasheet.
Summary
Product Identification
ROGA® - HR 4” & 8” elements are Cellulose Acetate, Reverse Osmosis elements.
- Membrane Chemistry: Proprietary ROGA cellulose acetate
- Membrane Type: ROGA membrane
- Construction: Spiral-wound with fiberglass outerwrap
- Applications: High rejection for municipal water treatment, municipal wastewater reclamation, industrial water supply, and where chlorine is needed on a regular basis
- Options: 40” (1,016 mm) or 60” (1,524 mm) Magnum® length
Specifications
Test conditions: 2,000 mg/l NaCl solution at 420 psi (2,900 kPa) applied pressure, 15% recovery (20% recovery for Magnum elements), 77°F (25°C) and pH 5.7.
| Part Numbers | Model | Permeate Flow (gpd) | Permeate Flow (m³/d) | Chloride Rejection (percent) | Membrane Area (ft²) | Membrane Area (m²) |
|---|---|---|---|---|---|---|
| 8422100 | 4221 HR | 1,600 | 6.1 | 98.0 | 81 | 7.5 |
| 8822200 | 8222 HR | 6,900 | 26.1 | 98.0 | 340 | 31.6 |
| 8823200 | 8232 HR Magnum® | 11,500 | 43.5 | 98.0 | 520 | 48.3 |
Performance Notes:
- Individual element permeate flows may vary ±15% from the values shown.
- Minimum chloride ion rejection is 97% at the specified test conditions.
- System performance should be predicted using KMS’ ROPRO® design software.
- System operating data should be normalized and tracked using KMS’ NORMPRO® software.
Operating Limits
- Operating Pressure:
- Typical: 420 psi (2,900 kPa)
- Maximum: 600 psi (4,140 kPa)
- Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
- Temperature:
- Maximum operating: 104°F (40°C)
- Maximum cleaning: 104°F (40°C)
- pH:
- Allowable for continuous operation: 4 – 6
- Allowable for short term cleaning: 2.5 – 7
- Recovery:
- Single element recovery: approximately 15% for 40” (1,016 mm) long elements; 20% for 60” (1,524 mm) long elements.
- Maximum recovery is site and application specific and should be determined using KMS’ ROPRO program.
Feed water
- Maximum continuous free chlorine: 1 mg/l (or similarly active oxidizing agents such as iodine, bromine, and ozone, as free chlorine equivalent)
- Maximum feed turbidity: 1 NTU (feedwater with turbidity greater than 0.2 NTU generally results in frequent cleanings)
- Maximum feed SDI (15 minute): 5
- Feedwater pH adjustment: pH should be adjusted to a practical value of approximately 5.7 to minimize membrane hydrolysis. Effects may become significant above pH 6.
- Feed spacer thickness: KMS recommends 31 mil (0.8 mm) thick feed spacers (standard construction) for applications with higher fouling potential.
Mechanical / Hydraulic
- Maximum differential pressure per element:
- 10 psi (69 kPa) for a 40” (1,016 mm) long element
- 15 psi (104 kPa) for a 60” (1,524 mm) long element
- Maximum differential pressure per vessel: 60 psi (414 kPa)
Product Dimensions and Weight
| Model | A (inches) | A (mm) | B (inches) | B (mm) | C (inches) | C (mm) | Weight (lbs) | Weight (kg) | Interconnector | O-ring | Brine Seal |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4221 HR | 40 | 1,016 | 4 | 101.6 | 0.625 | 15.9 | 10 | 4.5 | 0035262 | 0035468 | 0035702 |
| 8222 HR | 40 | 1,016 | 8 | 203.2 | 1.125 | 28.6 | 40 | 18.0 | 0035260 | 0035464 | 0035705 |
| 8232 HR Magnum® | 60 | 1,524 | 8 | 203.2 | 1.125 | 28.6 | 58 | 26.4 | 0035260 | 0035464 | 0035705 |
Lubricants: For element loading, use only recommended silicone lubricant (or approved equivalent), water, or glycerin to lubricate O-rings and brine seals. Petroleum or vegetable based lubricants may damage the element and void the warranty.
Disclaimer: This extraction may miss figures, footnotes, or revisions present in the original PDF. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.