Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

TFC-FR8 / TFC 8822 FR-400

Engineering summary from PDF text extraction for TFC-FR8 / TFC 8822 FR-400. Verify every value with the OEM datasheet.

Summary

Product identification

FLUID SYSTEMS TFC®-FR 8” fouling resistant, low pressure, reverse osmosis (RO) elements for brackish surface water or wastewater treatment.

  • Membrane Chemistry: Proprietary TFC® polyamide
  • Membrane Type: TFC®-FR, fouling resistant
  • Construction: Spiral-wound with fiberglass outerwrap
  • Applications: Fouling resistant membrane for surface water and wastewater treatment
  • Options: 40” (1,016 mm) length with standard or high area construction, or 60” (1,524 mm) Magnum® length.

Specifications

Test Conditions: 2,000 mg/l NaCl solution at 225 psi (1,550 kPa) applied pressure, 15% recovery (20% recovery for Magnum® elements) 77°F (25°C) and pH 7.5.

ModelPermeate Flow gpd (m³/d)Chloride Rejection percentMembrane Area ft² (m²)
TFC® 8822 FR-3659,500 (36.0)99.5365 (33.9)
TFC® 8822 FR-40010,500 (39.7)99.5400 (37.2)
TFC® 8832 FR-575 Magnum®15,000 (56.8)99.5575 (53.4)

Operating limits

  • Typical operating pressure: 225 - 450 psi (1,550 - 3,100 kPa)
  • Maximum operating pressure: 600 psi (4,140 kPa)
  • Maximum operating temperature: 113°F (45°C)
  • Maximum cleaning temperature: 113°F (45°C)
  • Maximum continuous free chlorine: <0.1 mg/l
  • Allowable pH - continuous operation: 4 - 11
  • Allowable pH - short term cleaning: 2.5 - 11
  • Maximum differential pressure per 40”/60” element: 10/15 psi (69/104 kPa)
  • Maximum differential pressure per vessel: 60 psi (414 kPa)
  • Maximum feed turbidity: 1 NTU
  • Maximum feed SDI (15 minute): 5
  • Feed spacer thickness standard/high area: 31/28 mil (0.8/0.7 mm)

Mechanical / hydraulic

Physical dimensions and weights for various models:

ModelA inches (mm)B inches (mm)C inches (mm)Weight lbs (kg)
TFC® 8822 FR-36540 (1,016)8 (203.2)1.125 (28.6)40 (18)
TFC® 8822 FR-40040 (1,016)8 (203.2)1.125 (28.6)44 (20)
TFC® 8832 FR-575 Magnum®60 (1,524)8 (203.2)1.125 (28.6)64 (29)

Note: A, B, C refer to the dimensions depicted in the original document as Length, Diameter, and Core Diameter, respectively.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used for your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.