Datasheet summary
TFC 8822 HR-400
Engineering summary from PDF text extraction for TFC 8822 HR-400. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: FLUID SYSTEMS® TFC® - HR 8” ELEMENTS
- Description: High Rejection, Low Pressure RO Elements for Brackish Water
- Membrane Type: Proprietary TFC® HR polyamide
- Construction: Spiral wound with fiberglass outerwrap
- Applications: High rejection for brackish water treatment
- Length Options: 40” (1,016 mm) or 60” (1,524 mm) Magnum®
- Feed Spacer Options: 28 or 31 mil
Specifications
Performance specifications are nominal values. Individual element permeate flows may vary +20%/-15% from the values shown. Minimum chloride ion rejection is 99.2% at the conditions shown.
| Part Numbers | Model | Permeate Flow gpd (m³/d) | Chloride Rejection percent | Membrane Area ft² (m²) | Feed Spacer mil (mm) |
|---|---|---|---|---|---|
| 8882200 | 8822 HR-365 | 10,300 (40.0) | 99.5 | 365 (33.9) | 31 (0.8) |
| 8882202 | 8822 HR-400 | 11,200 (42.4) | 99.5 | 400 (37.2) | 28 (0.7) |
| 8883205 | 8832 HR-575 Magnum® | 15,000 (56.8) | 99.5 | 575 (53.4) | 31 (0.8) |
| 8982200 | 9822 HR-400 | 10,500 (39.7) | 99.5 | 400 (37.2) | 31 (0.8) |
Test Conditions: 2,000 mg/l NaCl solution at 225 psi (1,550 kPa) applied pressure, 15% recovery (20% recovery for Magnum® elements), 77°F (25°C) and pH 7.5.
Operating limits
- Typical Operating Pressure: 150 - 250 psi (1,035 – 1,725 kPa)
- Maximum Operating Pressure: 600 psi (4,140 kPa)
- Maximum Operating Temperature: 113°F (45°C)
- Maximum Cleaning Temperature: 113°F (45°C)
- Allowable pH – Continuous Operation: 4 – 11
- Allowable pH – Short Term Cleaning: 2.5 – 11
- Maximum Differential Pressure Per Element:
- 40” length: 10 psi (69 kPa)
- Magnum®: 15 psi (104 kPa)
- Maximum Differential Pressure Per Vessel: 60 psi (414 kPa)
- Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition).
- Recovery: Maximum recovery is site and application specific. Single element recovery is approximately 15% for 40” long and 20% for 60” long elements.
Feed water
- Maximum Continuous Free Chlorine: <0.1 mg/l
- Maximum Feed Turbidity: 1 NTU (Feedwater with turbidity greater than 0.2 NTU generally results in frequent cleanings).
- Maximum Feed SDI (15 minute test): 5.0
Chemical Tolerance:
- Chlorine: Intentional exposure to free chlorine or other oxidizing agents (e.g., permanganate, ozone, bromine, iodine) is not recommended. TFC-HR membrane has a free chlorine tolerance of approximately 1,000 ppm-hours based on testing at 77°F (25°C), pH 8. This tolerance may be significantly reduced if catalyzing metals (e.g., iron) are present or if the pH and/or temperature are different. Sodium metabisulfite (without catalysts such as cobalt) is the preferred reducing agent.
- Chloramine: TFC-HR membrane has a chloramine tolerance of approximately 60,000 ppm-hours in the absence of free chlorine, based on testing at 77°F (25°C), pH 8.
- Cationic (Positively Charged) Polymers and Surfactants: TFC-HR membrane may be irreversibly fouled if exposed to cationic polymers or surfactants. Exposure to these chemicals during operation or cleaning is not recommended.
- Lubricants: For element loading, use only recommended silicone lubricant (or approved equivalent), water, or glycerin to lubricate O-rings and brine seals. Petroleum-based lubricants or vegetable-based oils may damage the element and void the warranty.
Mechanical / hydraulic
| Model | A inches (mm) | B inches (mm) | C inches (mm) | Weight lbs (kg) | Interconnector O-ring | Brine Seal |
|---|---|---|---|---|---|---|
| 8822 HR-365 | 40 (1,016) | 8 (203.2) | 1.125 (28.6) | 40 (18) | 0035260 | 0035705 |
| 8822 HR-400 | 40 (1,016) | 8 (203.2) | 1.125 (28.6) | 44 (20) | 0035260 | 0035705 |
| 8832 HR-575 Magnum® | 60 (1,524) | 8 (203.2) | 1.125 (28.6) | 64 (29) | 0035260 | 0035705 |
| 9822 HR-400 | 40 (1,016) | 8.5 (215.9) | 1.125 (28.6) | 44 (20) | 0035260 | 0035705 |