Datasheet summary
TFC-FR8 / TFC 8832 FR-575 Magnum
Engineering summary from PDF text extraction for TFC-FR8 / TFC 8832 FR-575 Magnum. Verify every value with the OEM datasheet.
Summary
Product identification
This document describes FLUID SYSTEMS TFC® - FR 8” Fouling Resistant, Low Pressure, Brackish Surface Water or Wastewater Treatment Reverse Osmosis Elements.
| Model | Permeate Flow gpd (m³/d) | Chloride Rejection percent | Membrane Area ft² (m²) |
|---|---|---|---|
| TFC® 8822 FR-365 | 9,500 (36.0) | 99.5 | 365 (33.9) |
| TFC® 8822 FR-400 | 10,500 (39.7) | 99.5 | 400 (37.2) |
| TFC® 8832 FR-575 Magnum® | 15,000 (56.8) | 99.5 | 575 (53.4) |
Test Conditions: Performance data determined using a 2,000 mg/l NaCl solution at 225 psi (1,550 kPa) applied pressure, 15% recovery (20% recovery for Magnum® elements), 77°F (25°C), and pH 7.5.
Operating limits
- Typical operating pressure: 225 - 450 psi (1,550 - 3,100 kPa)
- Maximum operating pressure: 600 psi (4,140 kPa)
- Maximum operating temperature: 113°F (45°C)
- Maximum cleaning temperature: 113°F (45°C)
- Maximum continuous free chlorine: <0.1 mg/l
- Allowable pH - continuous operation: 4 - 11
- Allowable pH - short term cleaning: 2.5 - 11
- Maximum differential pressure per 40”/60” element: 10/15 psi (69/104 kPa)
- Maximum differential pressure per vessel: 60 psi (414 kPa)
Feed water
- Maximum feed turbidity: 1 NTU
- Maximum feed SDI (15 minute): 5
Membrane Characteristics
- Membrane Chemistry: Proprietary TFC® polyamide
- Membrane Type: TFC® - FR, fouling resistant
- Construction: Spiral-wound with fiberglass outerwrap
- Feed spacer thickness standard/high area: 31/28 mil (0.8/0.7 mm)
Applications
Fouling resistant membrane for surface water and wastewater treatment.
Mechanical / hydraulic
| Model | A inches (mm) | B inches (mm) | C inches (mm) | Weight lbs (kg) | Part Numbers Interconnector | O-ring | Brine Seal |
|---|---|---|---|---|---|---|---|
| TFC® 8822 FR-365 | 40 (1,016) | 8 (203.2) | 1.125 (28.6) | 40 (18) | 0035260 | 0035464 | 0035705 |
| TFC® 8822 FR-400 | 40 (1,016) | 8 (203.2) | 1.125 (28.6) | 44 (20) | 0035260 | 0035464 | 0035705 |
| TFC® 8832 FR-575 Magnum® | 60 (1,524) | 8 (203.2) | 1.125 (28.6) | 64 (29) | 0035260 | 0035464 | 0035705 |
- Options: 40” (1,016 mm) length with standard or high area construction, or 60” (1,524 mm) Magnum® length.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.