Datasheet summary
TFC 8923 S 400/ Softening / Low pressure
Engineering summary from PDF text extraction for TFC 8923 S 400/ Softening / Low pressure. Verify every value with the OEM datasheet.
Summary
Product Identification
- Membrane Chemistry: Proprietary TFC polyamide
- Membrane Type: TFC-S membrane
- Construction: Spiral wound with fiberglass outerwrap
- Applications: Municipal water treatment when softening and THMFP (Trihalomethane Formation Potential) reduction
- Options: Available in 40” (1,106 mm) length with high area construction, or 60” (1,524 mm) Magnum® length.
Specifications
| Model | Permeate Flow (gpd) | Permeate Flow (m³/d) | Chloride Rejection (%) | Total Hardness Rejection (%) | MgSO₄ Rejection (%) | Membrane Area (ft²) | Membrane Area (m²) |
|---|---|---|---|---|---|---|---|
| 8923 S-400 | 9,000 | 34.1 | 85* | 98.5* | 99** | 400 | 37.2 |
| 8933 S-575 Magnum® | 12,500 | 47.3 | 85* | 98.5* | 99** | 575 | 53.4 |
* Test Conditions: Mixed feed with 700 mg/L TDS (at least 45% monovalent), 80 psi (550 kPa) applied pressure, 15% recovery (20% recovery for Magnum elements), 77°F (25°C) and pH 7.5. ** Test Conditions: 1,000 mg/L MgSO₄ in deionized water, 80 psi (550 kPa) applied pressure, 15% recovery (20% recovery for Magnum elements), 77°F (25°C) and pH 7.5.
Nominal vs. Minimum Performance:
- Individual element permeate flows may vary +20% / -15% from nominal values.
- Minimum chloride ion rejection: 85%
- Minimum total hardness rejection: 94% (at mixed feed conditions)
- Minimum MgSO₄ rejection: 95% (at MgSO₄ conditions)
Operating Limits
- Typical Operating Pressure: 80 psi (552 kPa)
- Maximum Operating Pressure: 350 psi (2,410 kPa)
- Maximum Operating Temperature: 113°F (45°C)
- Maximum Cleaning Temperature: 113°F (45°C)
- Maximum Continuous Free Chlorine: <0.1 mg/L
- Allowable pH (continuous operation): 4 – 11
- Allowable pH (short-term cleaning): 2.5 – 11
- Maximum Differential Pressure per Element:
- 40” (1,016 mm) long element: 10 psi (69 kPa)
- 60” (1,524 mm) long element: 15 psi (104 kPa)
- Maximum Differential Pressure per Vessel: 60 psi (414 kPa)
- Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
- Maximum Feed Turbidity: 1 NTU (Feedwater >0.2 NTU generally leads to frequent cleanings)
- Maximum Feed SDI (15 minute test): 5.0
- Feed Spacer Thickness: 31/28 mil (0.8/0.7 mm)
- Recovery: Approximately 15% for 40” long elements and 20% for 60” long elements. Maximum recovery is site and application specific.
Chemical Tolerance
- Chlorine: Intentional exposure to free chlorine or other oxidizing agents (e.g., permanganate, ozone, bromine, iodine) is not recommended.
- Free Chlorine Tolerance: Approximately 1,000 ppm-hours (at 77°F (25°C), pH 8). This tolerance can be reduced by catalyzing metals (e.g., iron) or different pH/temperature. Sodium metabisulfite is the preferred reducing agent.
- Chloramine Tolerance: Approximately 60,000 ppm-hours in the absence of free chlorine (at 77°F (25°C), pH 8).
- Cationic (Positively Charged) Polymers and Surfactants: TFC-S membranes may be irreversibly fouled; exposure during operation or cleaning is not recommended.
Product Dimensions and Weight
| Model | Dim A inches (mm) | Dim B inches (mm) | Dim C inches (mm) | Weight lbs (kg) | Interconnector | O-ring | Brine Seal |
|---|---|---|---|---|---|---|---|
| 8923 S-400 | 40 (1,016) | 8 (203.2) | 1.5 (38.1) | 44 (20) | 0035270 | 0035478 | 0035705 |
| 8933 S-575 Magnum® | 60 (1,524) | 8 (203.2) | 1.5 (38.1) | 64 (29) | 0035270 | 0035478 | 0035705 |
Lubricants
For element loading, use only approved silicone lubricant (or equivalent), water, or glycerin for O-rings and brine seals. Petroleum-based or vegetable-based oils may damage the element and void the warranty.