Datasheet summary
TFC 9822 HR-400
Engineering summary from PDF text extraction for TFC 9822 HR-400. Verify every value with the OEM datasheet.
Summary
Product Identification
FLUID SYSTEMS® TFC®-HR 8” Elements are high rejection, low pressure reverse osmosis (RO) elements designed for brackish water treatment.
- Membrane Type: Proprietary TFC®-HR polyamide
- Construction: Spiral wound with fiberglass outerwrap
- Applications: High rejection for brackish water treatment
- Length Options: 40” (1,016 mm) or 60” (1,524 mm) Magnum®
- Feed Spacer Options: 28 or 31 mil
Product Specifications
Elements are tested at 2,000 mg/l NaCl solution at 225 psi (1,550 kPa) applied pressure, 15% recovery (20% recovery for Magnum® elements), 77°F (25°C), and pH 7.5.
| Model | Permeate Flow (gpd) | Permeate Flow (m³/d) | Chloride Rejection (%) | Membrane Area (ft²) | Membrane Area (m²) | Feed Spacer (mil) | Feed Spacer (mm) |
|---|---|---|---|---|---|---|---|
| 8822 HR-365 | 10,300 | 40.0 | 99.5 | 365 | 33.9 | 31 | 0.8 |
| 8822 HR-400 | 11,200 | 42.4 | 99.5 | 400 | 37.2 | 28 | 0.7 |
| 8832 HR-575 Magnum® | 15,000 | 56.8 | 99.5 | 575 | 53.4 | 31 | 0.8 |
| 9822 HR-400 | 10,500 | 39.7 | 99.5 | 400 | 37.2 | 31 | 0.8 |
Operating Limits
- Typical Operating Pressure: 150 - 250 psi (1,035 – 1,725 kPa)
- Maximum Operating Pressure: 600 psi (4,140 kPa)
- Maximum Operating Temperature: 113°F (45°C)
- Maximum Cleaning Temperature: 113°F (45°C)
- Allowable pH – Continuous Operation: 4 – 11
- Allowable pH – Short Term Cleaning: 2.5 – 11
- Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
- Maximum Differential Pressure Per Element:
- 40” elements: 10 psi (69 kPa)
- 60” Magnum® elements: 15 psi (104 kPa)
- Maximum Differential Pressure Per Vessel: 60 psi (414 kPa)
- Recovery:
- Single element (40”): approximately 15%
- Single element (60” Magnum®): approximately 20%
- Maximum recovery is site and application specific.
Feed Water
- Maximum Continuous Free Chlorine: <0.1 mg/l
- Maximum Feed Turbidity: 1 NTU (Feedwater with turbidity greater than 0.2 NTU generally results in frequent cleanings.)
- Maximum Feed SDI (15 minute test): 5.0
Product Water
- Nominal Chloride Rejection: 99.5%
- Minimum Chloride Ion Rejection: 99.2% at test conditions.
- Individual element permeate flows may vary +20%/-15% from the nominal values.
Mechanical / Hydraulic
Product Dimensions
| Model | A: Length (inches) | A: Length (mm) | B: Diameter (inches) | B: Diameter (mm) | C: Central Tube ID (inches) | C: Central Tube ID (mm) | Weight (lbs) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| 8822 HR-365 | 40 | 1,016 | 8 | 203.2 | 1.125 | 28.6 | 40 | 18 |
| 8822 HR-400 | 40 | 1,016 | 8 | 203.2 | 1.125 | 28.6 | 44 | 20 |
| 8832 HR-575 Magnum® | 60 | 1,524 | 8 | 203.2 | 1.125 | 28.6 | 64 | 29 |
| 9822 HR-400 | 40 | 1,016 | 8.5 | 215.9 | 1.125 | 28.6 | 44 | 20 |
- Interconnector O-ring: Part Number 0035260
- Brine Seal: Part Number 0035705
Chemistry
Chemical Tolerance
- Chlorine: Intentional exposure of TFC®-HR membrane to free chlorine or other oxidizing agents (e.g., permanganate, ozone, bromine, iodine) is not recommended.
- Free chlorine tolerance is approximately 1,000 ppm-hours based on testing at 77°F (25°C), pH 8. This tolerance may be significantly reduced if catalyzing metals (e.g., iron) are present or if pH and/or temperature are different.
- Sodium metabisulfite (without catalysts such as cobalt) is the preferred reducing agent.
- Chloramine tolerance is approximately 60,000 ppm-hours in the absence of free chlorine, based on testing at 77°F (25°C), pH 8.
- Cationic (Positively Charged) Polymers and Surfactants: Exposure to these chemicals during operation or cleaning is not recommended, as TFC®-HR membrane may be irreversibly fouled.
Lubricants
For element loading, use only the recommended silicone lubricant (or approved equivalent), water, or glycerin to lubricate O-rings and brine seals. The use of petroleum-based lubricants or vegetable-based oils may damage the element and void the warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions of the OEM PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.