Datasheet summary
TFC-8040-SR100-260 Low Pressure Nanofiltration
Engineering summary from PDF text extraction for TFC-8040-SR100-260 Low Pressure Nanofiltration. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: FLUID SYSTEMS® TFC® SR100 8” ELEMENTS
- Description: Low Pressure, Selective Rejection Nanofiltration Elements
- Membrane Chemistry: Proprietary TFC® polyamide
- Membrane Type: SR100 – selective rejection nanofiltration membrane
- Construction: Spiral wound with fiberglass outerwrap
- Applications: Separation of higher molecular weight components (>200 Dalton) and multivalent ions from various feed solutions, deashing.
- Feed Spacer Options: 31 mil (0.8 mm) and 46 mil (1.2 mm)
Model Specifications (8040-SR100-260)
- Part Number: 8872201
- Nominal Permeate Flow: 4,500 gpd (17.0 m³/d)
- MgSO₄ Rejection: > 99.0 percent
- Active Membrane Area: 260 ft² (24.1 m²)
- Feed Spacer: 46 mil (1.2 mm)
- Test Conditions: 5,000 mg/l MgSO₄ in deionized water at 95 psi (655 kPa) applied pressure, 15% recovery, 77°F (25°C), pH 7.5.
- Performance Variation: Individual element permeate flows may vary +20/-15% from nominal values.
Operating limits
- Typical Operating Pressure: 200 - 600 psi (1,380 - 4,140 kPa). Typical operating pressure for TFC SR100 systems is in the range of 150 psi (1,035 kPa) to 250 psi (1,725 kPa).
- Maximum Operating Pressure: 600 psi (4,140 kPa)
- Maximum Operating Temperature: 122°F (50°C)
- Maximum Cleaning Temperature: 113°F (45°C)
- Maximum Continuous Free Chlorine: <0.1 mg/l
- Allowable pH (Continuous Operation): 4 - 10
- Allowable pH (Short Term Cleaning): 1.7 – 11.5 (limit exposure to 4 hours, once per month)
- Maximum Differential Pressure Per Element: 10 psi (69 kPa)
- Maximum Differential Pressure Per Vessel: 60 psi (414 kPa)
- Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
- Single Element Recovery: Approximately 15% per element.
Feed water
- Maximum Feed Turbidity: 1 NTU
- Maximum Feed SDI (15 minute test): 5.0
- Chemical Tolerance (Free Chlorine): Approximately 2,000 ppm-hours (based on testing at 77°F (25°C), pH 8). Exposure to free chlorine or other oxidizing agents (e.g., permanganate, ozone, bromine, iodine) is not recommended.
- Chemical Tolerance (Chloramine): Approximately 60,000 ppm-hours (based on testing at 77°F (25°C), pH 8, in the absence of free chlorine).
- Cationic Polymers and Surfactants: Exposure to these chemicals during operation or cleaning is not recommended as the membrane may be irreversibly fouled.
Mechanical / Hydraulic
- Nominal Dimensions (Model 8040-SR100-260):
- A: 40 inches (1,016 mm)
- B: 8 inches (203 mm)
- C: 1.125 inches (29 mm)
- Weight (Model 8040-SR100-260): 44 lbs (20 kg)
- Accessory Part Numbers:
- Interconnector: 0035260
- O-ring: 0035464
- Brine Seal: 0035705
- Lubricants: For element loading, use only recommended silicone lubricant (or approved equivalent), water, or glycerin to lubricate O-rings and brine seals. Petroleum based lubricants or vegetable based oils may damage the element and void the warranty.
Disclaimer This summary is based on the provided text extract. The original PDF may contain additional figures, footnotes, or more recent revisions. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.