Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

3838 MFK-601

Engineering summary from PDF text extraction for 3838 MFK-601. Verify every value with the OEM datasheet.

Summary

Product identification

These are KMS MFK™ FOOD & DAIRY MF ELEMENTS, a series of Microfiltration 4”, 6” and 8” Spiral Elements.

  • Membrane Chemistry: Proprietary semi-permeable polyethersulfone (PES)
  • Membrane Type:
    • MFK™-618 with observed separation range of 0.1 micron
    • MFK™-601 with observed separation range of 0.4 micron
  • Construction: Sanitary spiral wound with net outer wrap
  • Regulatory Status: Conform to USDA 3-A standards and FDA regulations (CFR Title 21)
  • Options:
    • Diameter: 3.8”, 6.3”, or 8.3”
    • Feed Spacer: N (31 mil), V (46 mil), H (62 mil), F (80 mil), D (100 mil), or E (135 mil)
    • Outer wrap: Controlled (e.g. NYV) or trimmable (e.g. NYT)

Specifications

Active Membrane Area (Note: not all combinations available)

ModelSpacer TypeActive Area ft² (m²)
3838 MFK-618NYV/T (31 mil)60 (5.6)
VYV/T (46 mil)49 (4.6)
HYV/T (62 mil)41 (3.8)
FYV/T (80 mil)33 (3.1)
3838 MFK-601FYV/T (80 mil)33 (3.1)
6338 MFK-618HYV/T (62 mil)169 (15.7)
8338 MFK-618HYV/T (62 mil)290 (27.0)
FYV/T (80 mil)229 (21.3)
DYV/T (100 mil)185 (17.2)
EYV/T (135 mil)159 (14.8)
8338 MFK-601DYV/T (100 mil)185 (17.2)
  • Membrane Characteristics: The membrane consists of a semipermeable polyethersulfone (PES) layer on a polyester backing material.
  • Pure water flux (both MFK-601 and MFK-618): 2.0-4.4 gfd/psi at 77°F (25°C).

Operating limits

  • Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar)
  • Maximum Operating Pressure: 140 psi (9.7 bar)
    • Permeate pressure should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane.
  • Typical Operating Temperature Range: 41 - 131°F (5 - 55°C)
  • Maximum Operating Temperature:
    • At pH 6.0 - 7.5: 150°F (65.5°C)
    • At pH 3.5 - 6.0: 140°F (60°C)
    • At pH 2.0 - 3.5 and 7.5 – 10.0: 131°F (55°C)
  • Cleaning (CIP) Temperature Range: 104 - 122°F (40 - 50°C)
    • Maximum cleaning temperature is 122°F (50°C).
  • Allowable pH - Continuous Operation: 2.0 - 10.0
  • Allowable pH - Clean-In-Place (CIP): 1.8 - 11.0
  • Design Pressure Drop Per Element:
    • N spacer: 5-15 psi (0.3-1.0 bar)
    • V spacer: 5-20 psi (0.3-1.4 bar)
    • H, F, D or E spacer: 10-20 psi (0.7-1.4 bar)
  • Design Pressure Drop Per Vessel (3 In Series):
    • N spacer: 15-45 psi (1.0-3.1 bar)
    • V spacer: 15-60 psi (1.0-4.1 bar)
    • H, F, D or E spacer: 30-60 psi (2.1-4.2 bar)
  • Water Quality for Cleaning & Diafiltration:
    • Maximum feed turbidity: 1 NTU
    • Maximum feed SDI: 5.0 (15-minute test)
  • Chlorine and Chemical Exposure:
    • Recommended chlorine exposure time: 30 minutes per day.
    • Residual chlorine concentration during cleaning cycle (CIP) should be 150 ppm @ pH 10.5 or higher.
    • Chlorine concentration should never exceed 200 ppm.
    • Chlorine should only be added to the cleaning solution after the pH has been adjusted to 10.5 or higher.
    • Iron or other catalyzing metals in the presence of free chlorine or hydrogen peroxide will accelerate membrane degradation.
  • Cationic (Positively Charged) Polymers and Surfactants: Exposure to these chemicals during operation or cleaning is not recommended and will void the warranty, as MFK membranes may be irreversibly fouled.
  • Lubricants: For module installation, use only water or glycerin to lubricate seals. The use of petroleum or vegetable-based oils or solvents may damage the element and will void the warranty.

Mechanical / hydraulic

Nominal Dimensions

ModelA (inches (mm))B (inches (mm))C (inches (mm))
3838 MFK-601/61838.0 (965)3.8 (96)0.831 (21.1)
6338 MFK-61838.0 (965)6.3 (160)1.138 (28.9)
8338 MFK-601/61838.0 (965)8.3 (211)1.138 (28.9)

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.