Datasheet summary
8338-MFK-603-FYT
Engineering summary from PDF text extraction for 8338-MFK-603-FYT. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: KMS MFK™ FOOD & DAIRY MF ELEMENTS
- Membrane Chemistry: Proprietary semi-permeable polyethersulfone (PES) layer on a polyester backing material.
- Membrane Type: MFK™-603 with observed separation range of 0.1 micron
- Construction: Sanitary spiral wound with net outer wrap
- Regulatory Status: Conform to USDA 3-A standards and FDA regulations (CFR Title 21)
Models
- KMS Part Number: 0757063
- Model: 3838 MFK-603-FYV
- Active Membrane Area: 33 ft² (3.0 m²)
- Feed Spacer: 80 mil (2.0 mm)
- KMS Part Number: 0750703
- Model: 8338 MFK-603-FYT
- Active Membrane Area: 181 ft² (16.8 m²)
- Feed Spacer: 80 mil (2.0 mm)
Operating limits
- Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar)
- Maximum Operating Pressure: 140 psi (9.7 bar)
- Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time.
- Maximum Operating Temperature (Process): 176°F (80°C)
- Allowable pH - Continuous Operation: 2.0 - 10.0
- Allowable pH - Clean-In-Place (CIP): 1.8 - 11.0
- Design Pressure Drop Per Element: 10-20 psi (0.7-1.4 bar)
- Maximum Pressure Drop Per Vessel: 60 psi (4.2 bar)
Membrane Characteristics
- Membrane Material: Semipermeable polyethersulfone (PES) layer on a polyester backing material.
- Pure Water Flux (MFK-603): 2.0-4.4 gfd/psi at 77°F (25°C).
Cleaning & Chemical Exposure
- Cleaning (CIP) Temperature Range:
- For chlorine cleaning: 104 - 122°F (40 - 50°C)
- For cleaning not involving chlorine: 104 - 176°F (40 - 80°C)
- Recommended Chlorine Exposure Time: 30 minutes per day.
- Residual Chlorine Concentration (during CIP): 150 ppm @ pH 10.5 or higher.
- Maximum Chlorine Concentration: Never exceed 200 ppm.
- Chlorine Addition: Only to cleaning solution after pH has been adjusted to 10.5 or higher.
- Caution: Iron or other catalyzing metals in the presence of free chlorine or hydrogen peroxide will accelerate membrane degradation.
- Sanitizing: Should be done only after a complete cleaning cycle and with water of acceptable quality.
- Cationic Polymers and Surfactants: Exposure may cause irreversible fouling and voids warranty.
- Lubricants for Installation: Use only water or glycerin to lubricate seals. Petroleum or vegetable-based oils or solvents may damage the element and void the warranty.
Mechanical / hydraulic
Nominal Dimensions
| Model | A (inches) | A (mm) | B (inches) | B (mm) | C (inches) | C (mm) |
|---|---|---|---|---|---|---|
| 3838 MFK-603 | 38.0 | 965 | 3.8 | 96 | 0.831 | 21.1 |
| 8338 MFK-603 | 38.0 | 965 | 8.3 | 211 | 1.138 | 28.9 |