Datasheet summary
ABCOR FEG PLUS 10-HFM-251-PVI
Engineering summary from PDF text extraction for ABCOR FEG PLUS 10-HFM-251-PVI. Verify every value with the OEM datasheet.
Summary
Product Identification
This document describes the ABCOR™ FEG PLUS™ MODULE: 10-HFM-251-PVI, a tubular ultrafiltration one-inch module designed for industrial applications.
- KMS Part Number (KPN): 0711651
- Membrane Chemistry: PVDF
- Membrane Type: HFM (neutral)
- Membrane Area: 2.2 ft² (0.20 m²)
- Molecular Weight Cut-off: 100,000 Dalton (nominal)
- Housing Construction: CPVC
- Seal: CPVC Insert (Epoxied in Place)
- Gasket: Viton®
Operating Limits
- Maximum Inlet Pressure: 90 psi @ 140°F (6.2 bar @ 60°C)
- Minimum Outlet Pressure: 5 psi (0.3 bar)
- Maximum Operating Temperature (at pH 8.0): 140°F (60°C)
- Maximum Permeate Side Back Pressure: 5 psi (0.3 bar)
- Maximum Feed Side Pressure Drop: 10 psi @ 140°F (0.7 bar @ 60°C)
- Allowable pH - Continuous Exposure: 2.0 - 10.0 @ 140°F (60°C)
- Allowable pH - Short Term Exposure: 1.5 - 10.5 @ 140°F (60°C)
Consult KMS Process Technology for specific applications.
Feed Flow vs. Pressure Drop
Data based on water at 77°F (25°C) and specific gravity of 1.0. Circulation rates exhibit variances of 15%.
| Circulation Flow | Crossflow Velocity | Pressure Drop |
|---|---|---|
| gpm | m³/hr | fps |
| 19 | 4.3 | 7.8 |
| 30 | 6.8 | 12.3 |
| 38 | 8.6 | 15.5 |
Ancillary Parts
KMS recommends that these membranes be used with KMS supplied ancillary parts. Sealing is provided by o-rings and gaskets. No additional sealing compound or tape is recommended for use on threaded connections.
- 1 Terminator Kit (KPN: 0230020)
- Includes: Holding Nut, PVC (x2); Nipple, PVC (x2); Snap Ring, SS304 (x2)
- 2 U-Bend Assembly, CPVC (KPN: 0020392)
- 3 Holding Nut (PVC) (KPN: 0020281)
- 4 Snap Ring, SS304 (KPN: 0020310)
- 5 Membrane Washer, Viton® (KPN: 0020375)
- 6 Permeate Straight Connector (KPN: 0211800)
- 7 Permeate Pass Kit (for 4 tubes) (KPN: 0211786)
- Includes: O-Ring 2-112 (x4); Adapter ¼ to 3/8 (x1); Permeate Tee Connector (x4); Permeate Elbow Connector (x4); PE tubing
- 8 Permeate Tee Connector (KPN: 0211803)
- 9 Permeate Elbow Connector (KPN: 0211804)
- 10 Interconnector Kit, CPVC (KPN: 0230091)
- Includes: CPVC interconnector (x1); PVC Nut Holding (x2); Snap-Ring (x2)
Membrane Incompatibility
Prior to exposing the membrane to any chemical, the chemical should be reviewed by Koch Membrane Systems. Aside from the listed chemicals below, synthetic coolants, semi-synthetic coolants, kerosenes, naphtha, gasoline, floc polymers may affect membrane performance.
Chemicals that should be avoided include the following:
- Aprotic Solvent (e.g., Dimethyl Formamide, Dimethyl Acetamide, N-Methyl Pyrolidine, etc.)
- Chlorinated Solvents (e.g., Methylene Chloride, Chloroform, Carbon Tetrachloride, etc.)
- Ketones (e.g., Acetone, Diacetone Alcohol, etc.)
- Silicones or Silicone based Defoamers (e.g., Siloxane)