Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

SelRO 8040 MPS-36-NYHN

Engineering summary from PDF text extraction for SelRO 8040 MPS-36-NYHN. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Series: SelRO™ MPS-36 pH STABLE ELEMENTS Nanofiltration Spiral Element Series - 8040
  • Membrane Chemistry: Proprietary composite nanofiltration membrane
  • Membrane Type: pH stable nanofiltration membrane
  • Molecular Weight Cut-Off (MWCO): 1000 Daltons
  • Construction: Spiral wound element with hard overwrap and polysulfone permeate tube
  • Major Applications: Acid and caustic recovery, product concentration
  • Options: Feed channel spacers: 31 mil (N) and 57 mil (Z)

Specifications* Test Conditions: RO water at 440 psi (30 bar), 86°F (30°C). Feed solution for rejection tests is 3% glucose / 3% sucrose or 5% NaCl.

ModelPart NumberRejection [%] Glucose / SucroseRejection [%] NaClPermeate Flow gpd (m³/day)Membrane Area ft² (m²)Feed Spacer mil (mm)
8040 MPS-36-NYHN077025730 / 501036,250 (137)308 (28.6)31 (0.8)
8040 MPS-36-ZYHN077025830 / 501025,100 (95)210 (19.5)57 (1.4)

Operating limits

  • Typical Operating Pressure: 220-510 psi (15-35 bar)
  • Maximum Operating Pressure: 510 psi (35 bar)
  • Maximum Temperature: 158°F (70°C)
  • Allowable pH (Continuous Operation): 1-13
  • Allowable pH (Clean-In-Place, CIP): 1-13
  • Maximum Pressure Drop Per Element: 10 psi (0.7 bar)
  • Maximum Pressure Drop Per Vessel: 50 psi (3.5 bar)
  • Maximum Permeate Pressure: 3 psi (0.2 bar)
  • Feed Flow Rate:
    • Minimum: 25 gpm (95 liter/min)
    • Maximum: 75 gpm (285 liter/min)
  • Operating Envelope: An "Operating Envelope" diagram providing pressure-temperature relationship guidelines to prevent irreversible compaction and performance deterioration exists, especially for temperatures higher than 122°F (50°C). See the official PDF for exact tabulated values and the diagram.

Feed water

  • Turbidity: Maximum 1 NTU for best performance.
  • Chlorine and Chemical Exposure:
    • Exposure to chlorine or other oxidants is not recommended as it may affect membrane performance.
    • Sodium metabisulfite (without catalysts such as cobalt) is the preferred chemical to eliminate free chlorine or other oxidizers in the feed.
    • Exposure to organic solvents (e.g., alcohol, acetone) is not recommended.

Mechanical / hydraulic

Nominal Dimensions

ModelA inches (mm)B inches (mm)C inches (mm)InterconnectorO-Rings
8040 MPS-30-NYHN40.0 (1016)7.93 (202)1.125 (28.6)00305850035464
8040 MPS-30-ZYHN40.0 (1016)7.93 (202)1.125 (28.6)00305850035464

Element Handling:

  • Recommended Cleaning Materials:
    • 0.1-5% w/w sodium hydroxide at 122°F (50°C)
    • 0.2-1% w/w nitric or phosphoric acid at 122°F (50°C)
    • 0.1-0.5% w/w detergent mix KOCHKLEEN™ KLD-III
    • 0.5% anionic surfactant (such as SDS) at 122°F (50°C)
  • Lubricants: Use only water or glycerin to lubricate seals. Petroleum or vegetable-based oils or solvents may damage the element and will void any warranty.
  • Storage Solution:
    • Short Term (up to two weeks): 0.25% w/w sodium metabisulfite.
    • Long Term: 0.7% w/w benzalkonium chloride.
    • Glycerin should not be used for storage of SelRO elements.
    • The membrane element should not get dry. Store in a sealed bag, in a temperature ranging from 36°F - 86°F (2°C - 30°C).

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF. For contractual data, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)