Datasheet summary
Spirapak 4038-HFM-183-LPP3
Engineering summary from PDF text extraction for Spirapak 4038-HFM-183-LPP3. Verify every value with the OEM datasheet.
Summary
Product identification
This document describes the SPIRAPAK™ MODULE: 4038-HFM-183-LPP3, a spiral ultrafiltration module designed for cathodic electrocoat paint applications.
- KMS Part Number: 0750782
- Membrane Chemistry: PVDF
- Membrane Type: HFM (positive charge)
- Membrane Area: 78 ft² (7.2 m²)
- Construction: Spiral wound element with integrated PVC housing
- Seal: EPDM
- Feed Spacer Thickness: 0.030” (0.7 mm)
Operating limits
- Maximum Inlet Pressure: 80 psi @ 125°F (5.5 bar @ 52°C)
- Maximum Operating Temperature: 125°F (52°C)
- Allowable pH – Continuous Operation: 3 – 7 @ 125°F (52°C)
- Allowable pH – Short Term Cleaning: 2 – 7 @ 125°F (52°C)
- Maximum Feed Side Pressure Drop: 40 psi @ 125°F (2.8 bar @ 52°C)
- Maximum Permeate Pressure: 5 psi (0.3 bar)
Mechanical / hydraulic
- Nominal Dimensions:
- A: 49.6 inches (1,260 mm)
- B: 56.4 inches (1,430 mm)
- C: 2.5 inches (64 mm)
- Working Weight: 45 lbs (20 kg)
- Process Connections: 1¼ NPSM
- Permeate Connection Options: The PDF lists three permeate connection options in the assembly section: 5/8” OD Rigid Tubing, ½” ID Flex hose, and 1½” Sanitary ferrule.
Membrane Incompatibility
The following chemicals and chemical types should be avoided or reviewed by Koch Membrane Systems prior to exposing the membrane:
- Aprotic Solvents (e.g., Dimethyl Formamide, Dimethyl Acetamide, N-Methyl Pyrolidine)
- Chlorinated Solvents (e.g., Methylene Chloride, Chloroform, Carbon Tetrachloride)
- Ketones (e.g., Acetone, Diacetone Alcohol)
- Silicones or Silicone based Defoamers (e.g., Siloxane)
- Synthetic coolants, semi-synthetic coolants, kerosenes, naphtha, gasoline, and floc polymers may also affect membrane performance.
Module Assembly
The PDF provides a detailed list of items, descriptions, quantities, and part numbers (KPN) required for the SPIRAPAK module assembly, including various permeate connection options. See the official PDF for exact tabulated values.
Disclaimer