Datasheet summary
Kpak 8638-M-183-LPP
Engineering summary from PDF text extraction for Kpak 8638-M-183-LPP. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Description: E-Coat Ultrafiltration Modules
- KMS Part Number (KPN): 0750785
- Membrane Chemistry: PVDF
- Membrane Type: HFM (Positive Charge)
- Membrane Area: 288 ft² (26.7 m²)
- Construction: Spiral wound element with integrated PVC housing
- Feed Spacer Thickness: 30 mils (0.76 mm)
- Interconnecting Components: See page 2 of the official PDF.
Operating limits
- Maximum Inlet Pressure at 110 °F (43 °C): 80.0 psi (5.5 bar)
- Maximum Inlet Pressure at 120 °F (49 °C): 64.0 psi (4.4 bar)
- Minimum Outlet Pressure: 10.0 psi (0.70 bar)
- Maximum Operating Temperature at 56 psi (3.9 bar): 125 °F (51.6 °C)
- Maximum Permeate Side Back Pressure: 5.0 psi (0.34 bar)
- Maximum Feed Side Pressure Drop at 125º F (51.6 º C): 35.0 psi (2.4 bar)
- Allowable pH – Continuous Exposure at 125 °F (51.6 °C): 2.0 – 10.0 pH
- Allowable pH – Short Term Exposure at 125 °F (51.6 °C): 1.5 – 10.5 pH
Note: Koch Membrane Systems, Inc. must review operating and cleaning conditions for all new plants and any changes to existing plants.
Mechanical / hydraulic
- Element Length: 39.25 in (997.0 mm)
- Element O.D.: 8.63 in (219.2 mm)
- Permeate Tube I.D.: 1.3 in (33.0 mm)
- Element Shipping Weight: 70 lbs (32 kg)
- Element Working Weight: 90 lbs (40.82 kg)
Feed Flow vs. Pressure Drop (Typical) (Data are based on water @ 77 ºF and a specific gravity of 1.0)
- Circulation Flow / Pressure Drop:
- 62 gpm (14.1 m³/hr) / 25 psi (1.7 bar)
- 70 gpm (15.9 m³/hr) / 30 psi (2.1 bar)
- 75 gpm (17.0 m³/hr) / 35 psi (2.4 bar)
KPAK Spiral Module Assembly Kits
- KPN 0211860 – Kit for New Systems
- KPN 0211851 – Retrofit Kit with 2” Process Ports
- KPN 0211858 – Retrofit Kit with 1 ½ ” Process Ports
For a detailed list of KPAK Spiral Element components including materials and KPNs, see the official PDF.