Datasheet summary
Pulsion Puron Hollow Fiber Rows
Engineering summary from PDF text extraction for Pulsion Puron Hollow Fiber Rows. Verify every value with the OEM datasheet.
Summary
Product identification
The PURON® Hollow Fiber Submerged Membrane Row is designed for MBR Applications, specifically the PULSION™ HOLLOW FIBER ROWS product line.
- Membrane Chemistry: Proprietary PVDF
- Membrane Type: Braided hollow fiber for outside-in operation
- Fiber Support Chemistry: Polyester
- Nominal Pore Size: 0.03 µm
- Outside Fiber Diameter: 0.1 inch (2.6 mm)
- Regulatory Information: Accepted by California Department of Public Health (CDPH) for compliance with California Water Recycling Criteria (Title 22)
- Potting Material: Proprietary epoxy compound
- Storage Solution: Glycerin
Product Specifications
- Part Number: 0728320
- Membrane Area: 468 ft² (43.5 m²)
Operating limits
- Temperature Range: 41 - 104°F (5 - 40°C)
- Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)
- Maximum Backflush Transmembrane Pressure: 9 psi (0.6 bar)
- Allowable pH Range for Cleaning: 2.0 – 10.5
- Maximum Allowed Total Chlorine @ 95°F (35°C) or Lower: 1,000 ppm @ pH 8 or higher during maintenance clean
- Maximum Allowed Total Chlorine @ 95°F (35°C) or Lower: 2,000 ppm @ pH 8 or higher during recovery clean
- Maximum Allowed Total Chlorine Contact: 500,000 ppm-hrs cumulative
Consult Process Technology Group for specific applications.
Mechanical / hydraulic
- Part Number: 0728320
- Length (L): 3.2 Inches (83 mm)
- Width (W): 33.6 Inches (853 mm)
- Height (H): 96 Inches (2,438 mm)
- Dry Weight: 108 Pounds (49 kg)
- Connections: Socket coupling. Connection kit is required for pilot use.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data and complete information, always refer to the specific OEM PDF revision used on your project.