Puron PSH 31HD

Engineering summary from PDF text extraction for Puron PSH 31HD. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: PURON® HOLLOW FIBER ROWS
  • Description: Hollow Fiber Submerged Membrane Row for MBR Applications
  • Membrane Chemistry: Proprietary PVDF
  • Membrane Type: Braided hollow fiber for outside-in operation
  • Fiber Support Chemistry: Polyester
  • Nominal Pore Size: 0.03 µm
  • Outside Fiber Diameter: 0.1 inch (2.6 mm)
  • Regulatory Information: Accepted by California Department of Public Health (CDPH) for compliance with California Water Recycling Criteria (Title 22)
  • Potting Material: Proprietary epoxy compound
  • Storage Solution: Glycerin

Product specifications

ModelMembrane Area ft² (m²)
PSH 31HD330 (31)
PSH 31330 (31)
PSH 34370 (34)
PSH 37400 (37)
PSH 41440 (41)

Operating limits

  • Temperature Range: 41 - 104°F (5 - 40°C)
  • Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)
  • Maximum Backflush Transmembrane Pressure: 9 psi (0.6 bar)
  • Allowable pH Range for Cleaning: 2.0 – 10.5
  • Maximum Allowed Total Chlorine @ 95°F (35°C) or Lower:
    • 1,000 ppm @ pH 8 or higher during maintenance clean
    • 2,000 ppm @ pH 8 or higher during recovery clean
  • Maximum Allowed Total Chlorine Contact: 500,000 ppm-hrs cumulative
  • Consult Process Technology Group for specific applications.

Mechanical / hydraulic

ModelL Inches (mm)W Inches (mm)H Inches (mm)Dry Weight Pounds (kg)
PSH 31HD3.62 (92)32.60 (828)71.69 (1,821)48.5 (22)
PSH 313.62 (92)32.60 (828)84.68 (2,151)50.7 (23)
PSH 343.62 (92)32.60 (828)91.30 (2,319)52.9 (24)
PSH 373.62 (92)32.60 (828)84.68 (2,151)57.3 (26)
PSH 413.62 (92)32.60 (828)91.30 (2,319)61.7 (28)
  • Connections: All connections: d40 threaded union

Storage and handling

Storage of unused PURON modules

  • Store within a temperature range of 41 to 77°F (5 to 25°C).
  • Store in the original packaging material.
  • Extended exposure to UV source must be avoided.
  • Must not be stored for longer than 3 months after delivery.

Transport of PURON modules

  • During transport, modules should be stored within a temperature range of 23 to 113°F (-5 to 45°C).
  • Should not be kept at temperatures outside the normal storage range of 41 to 77°F (5 to 25°C) for more than 6 weeks.
  • For ship transport, modules should be placed in seaworthy packaging and stored at ambient temperature, provided it is within the specified range.

Dry-Out protection

Once immersed in an aqueous medium, a PURON module should never be stored dry.

  • Shutdown 7 days or less: Module may be kept wet by submerging in the biomass, provided:
    • The biomass is healthy, aerated, and recirculation over the membrane chamber is functioning properly.
    • The module is fully submerged in the biomass.
    • Module aeration is switched on every 30 minutes for a period of 1 minute to assure mixing of sludge inside the module.
  • Shutdown longer than 7 days: Immersion in a storage solution is required. Consult KMS for more information.
  • If used PURON modules are permitted to dry out, membrane performance, such as permeability, may be adversely affected. Consult KMS for potential reversal steps.

Proper handling of PURON modules

  • Utmost care should be taken at all times.
  • Collisions, impact, or hitting the ground roughly may damage modules or connections.
  • Keep modules free from contact with sharp or abrasive objects or exposure to heat sources.
  • Actions that may cause sparks (e.g., welding, grinding) should be strictly prohibited in the vicinity of the modules.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data must match the specific OEM PDF revision used on the project.