Datasheet summary
Puron PSH 31HD
Engineering summary from PDF text extraction for Puron PSH 31HD. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: PURON® HOLLOW FIBER ROWS
- Description: Hollow Fiber Submerged Membrane Row for MBR Applications
- Membrane Chemistry: Proprietary PVDF
- Membrane Type: Braided hollow fiber for outside-in operation
- Fiber Support Chemistry: Polyester
- Nominal Pore Size: 0.03 µm
- Outside Fiber Diameter: 0.1 inch (2.6 mm)
- Regulatory Information: Accepted by California Department of Public Health (CDPH) for compliance with California Water Recycling Criteria (Title 22)
- Potting Material: Proprietary epoxy compound
- Storage Solution: Glycerin
Product specifications
| Model | Membrane Area ft² (m²) |
|---|---|
| PSH 31HD | 330 (31) |
| PSH 31 | 330 (31) |
| PSH 34 | 370 (34) |
| PSH 37 | 400 (37) |
| PSH 41 | 440 (41) |
Operating limits
- Temperature Range: 41 - 104°F (5 - 40°C)
- Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)
- Maximum Backflush Transmembrane Pressure: 9 psi (0.6 bar)
- Allowable pH Range for Cleaning: 2.0 – 10.5
- Maximum Allowed Total Chlorine @ 95°F (35°C) or Lower:
- 1,000 ppm @ pH 8 or higher during maintenance clean
- 2,000 ppm @ pH 8 or higher during recovery clean
- Maximum Allowed Total Chlorine Contact: 500,000 ppm-hrs cumulative
- Consult Process Technology Group for specific applications.
Mechanical / hydraulic
| Model | L Inches (mm) | W Inches (mm) | H Inches (mm) | Dry Weight Pounds (kg) |
|---|---|---|---|---|
| PSH 31HD | 3.62 (92) | 32.60 (828) | 71.69 (1,821) | 48.5 (22) |
| PSH 31 | 3.62 (92) | 32.60 (828) | 84.68 (2,151) | 50.7 (23) |
| PSH 34 | 3.62 (92) | 32.60 (828) | 91.30 (2,319) | 52.9 (24) |
| PSH 37 | 3.62 (92) | 32.60 (828) | 84.68 (2,151) | 57.3 (26) |
| PSH 41 | 3.62 (92) | 32.60 (828) | 91.30 (2,319) | 61.7 (28) |
- Connections: All connections: d40 threaded union
Storage and handling
Storage of unused PURON modules
- Store within a temperature range of 41 to 77°F (5 to 25°C).
- Store in the original packaging material.
- Extended exposure to UV source must be avoided.
- Must not be stored for longer than 3 months after delivery.
Transport of PURON modules
- During transport, modules should be stored within a temperature range of 23 to 113°F (-5 to 45°C).
- Should not be kept at temperatures outside the normal storage range of 41 to 77°F (5 to 25°C) for more than 6 weeks.
- For ship transport, modules should be placed in seaworthy packaging and stored at ambient temperature, provided it is within the specified range.
Dry-Out protection
Once immersed in an aqueous medium, a PURON module should never be stored dry.
- Shutdown 7 days or less: Module may be kept wet by submerging in the biomass, provided:
- The biomass is healthy, aerated, and recirculation over the membrane chamber is functioning properly.
- The module is fully submerged in the biomass.
- Module aeration is switched on every 30 minutes for a period of 1 minute to assure mixing of sludge inside the module.
- Shutdown longer than 7 days: Immersion in a storage solution is required. Consult KMS for more information.
- If used PURON modules are permitted to dry out, membrane performance, such as permeability, may be adversely affected. Consult KMS for potential reversal steps.
Proper handling of PURON modules
- Utmost care should be taken at all times.
- Collisions, impact, or hitting the ground roughly may damage modules or connections.
- Keep modules free from contact with sharp or abrasive objects or exposure to heat sources.
- Actions that may cause sparks (e.g., welding, grinding) should be strictly prohibited in the vicinity of the modules.