Datasheet summary
SelRO 3838 MPS-36-VYV
Engineering summary from PDF text extraction for SelRO 3838 MPS-36-VYV. Verify every value with the OEM datasheet.
Summary
Product identification
The SelRO™ NF SANITARY SPIRAL ELEMENT is a 4” acid and caustic stable nanofiltration spiral wound element.
- Membrane Chemistry: Proprietary composite nanofiltration membrane
- Membrane Type: MPS-36 pH stable nanofiltration membrane
- Molecular weight cut-off: 1,000 Daltons
- Construction: Sanitary spiral wound with net outerwrap
- Regulatory status: Compliant with US FDA CFR Title 21
- Permeate tube: Polysulfone
- Applications: Product concentration and purification
- Feed Spacer: 46 mil (1.2 mm)
Nominal Performance
Test conditions: RO water at 440 psi (30 bar), 86°F (30°C), 15% recovery, pH 7.5. Feed solution for rejection tests is 3% glucose / 3% sucrose or 5% NaCl. Rejection rates to sugars may vary and are given as indicative performance only.
- Part Number: 0770250
- Model: 3838 MPS-36-VYV
- Rejection:
- Glucose / Sucrose: 30 / 50
- NaCl: 10
- Permeate Flow: 7,100 gpd (26.9 m³/d)
- Active Membrane Area: 60 ft² (5.6 m²)
Operating limits
- Typical Operating Pressure: 145 - 510 psi (10 - 35 bar)
- Maximum Operating Pressure: 510 psi (35 bar)
- Operating Temperature Range: 40 - 158°F (5 - 70°C)
- Maximum Operating Temperature: 158°F (70°C)
- Cleaning Temperature Range: 95 - 158°F (35 - 70°C)
- Allowable pH - Continuous Operation: 1 - 13
- Allowable pH - Clean-In-Place (CIP): 1 - 13
- Design Pressure Drop Per Element: 6 - 10 psi (0.4 - 0.7 bar)
- Maximum Differential Pressure Per Single Element: 10 psi (0.7 bar) per housing
- Design Pressure Drop Per Vessel: 30 - 50 psi (2.1 - 3.4 bar)
- Maximum Differential Pressure Per Housing (any length): 50 psi (3.4 bar)
- Maximum Allowed Permeate Pressure: 3 psi (0.2 bar)
- Maximum Feed Flow Rate: 17 gpm (65 Liter per minute)
For specific applications, consult KMS Process Technology Group. Refer to the Operating Envelope for Code 30 Membranes Section when temperature is higher than 122°F (50°C). The operating envelope defines specific pressure-temperature relationships to prevent irreversible compaction and performance deterioration:
- 510 psi (35 bar) at 122°F (50°C)
- 360 psi (25 bar) at 140°F (60°C)
- 220 psi (15 bar) at 158°F (70°C) See the official PDF for the pressure-temperature diagram.
Feed water
- Maximum Feed Turbidity: 1 NTU
- Maximum Feed Silt Density Index (SDI): 5.0 (15-minute test)
- Chlorine and Chemical Exposure:
- Not recommended to expose the MPS-36 membrane to chlorine or other oxidants, as it may affect membrane performance.
- Sodium metabisulfite (without catalysts such as cobalt) is the preferred chemical to eliminate free chlorine or similar oxidizers in the feed.
- Not recommended to expose the membrane to organic solvents, such as alcohol, acetone, etc.
Mechanical / hydraulic
- Model: 3838 MPS-36-VYV
- A: 38.0 inches (965 mm)
- B: 3.8 inches (96 mm)
- C: 0.831 inches (21.1 mm)
Cleaning / Preservation
- Recommended Cleaning Materials:
- 0.1-5% w/w sodium hydroxide
- 0.2-1% w/w nitric or phosphoric acid
- 0.1-0.5% w/w detergent mix KOCHKLEEN™ KLD-III
- 0.5% Anionic surfactant (such as SDS)
- Preservation:
- Short Term (up to two weeks): 0.25 w/w Sodium metabisulfite
- Long Term: 0.7% w/w Benzalkonium chloride
- Concentrated glycerin should not be used to preserve the MPS-36 membrane.
Storage
- The membrane should not be permitted to get dry.
- It should be stored in a sealed bag, in temperature ranging from 25°F - 86°F (-4°C - 30°C).
Lubricants
- For element installation, use only water or glycerin to lubricate seals.
- The use of petroleum or vegetable-based oils or solvents may cause damage and will void any warranty.