Datasheet summary
SUPER-COR 3010-MFK-617
Engineering summary from PDF text extraction for SUPER-COR 3010-MFK-617. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: SUPER-COR® MICROFILTRATION MODULE
- Membrane Material: Polyethersulfone
- Membrane Type: Microfiltration MFK-617
- Nominal Pore Size*: 0.1 micron
- Configuration: Nineteen (19) ½” diameter tubules in a polysulfone shell
- Applications: Juice processing for dark juices
* The nominal separation range and retention characteristics of the membranes are highly dependent upon the nature of the liquid being processed and on several other operating parameters. This information should, therefore, be used as a guide only.
Regulatory information
Compliant with food contact regulations per US FDA CFR Title 21 and EC Reg. No. 1935/2004.
Specifications
- Part Number: 0712004
- Model: SUPER-COR® 3010-MFK-617
- Membrane Area: 24 ft² (2.2 m²)
Operating limits
- Maximum Operating Pressure: 90 psi @ 120°F (6.2 bar @ 49°C)
- Minimum Outlet Pressure: 10 psi (0.7 bar)
- Maximum Permeate Pressure: 3 psi (0.2 bar)
- Typical Feed Side Pressure Drop Per Module: 4-5 psi (0.27-0.35 bar)
- Maximum Feed Side Pressure Drop Per Module: 5 psi @ 120°F (0.35 bar @ 49 °C)
- Maximum Operating Temperature at pH 8:
- Continuous: 120°F (49°C)
- Short term: 130°F (54°C)
- Allowable pH Range at 120°F (49°C):
- Continuous: 2.0 – 10.0
- Short term: 1.5 – 10.5
- Maximum Chlorine (cleaning): 200 ppm @ pH 10-10.5, 120°F (49°C)
Mechanical / hydraulic
Nominal Dimensions:
- Diameter: 3.6” (91 mm)
- Overall Length: 120” (3048 mm)
- Additional nominal lengths indicated: 6” (152 mm), 115” (2921 mm)
- Sanitary connections: 3” Sanitary, 1” Sanitary
Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions of the official document. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.