Super G Plus Module HFM 500

Engineering summary from PDF text extraction for Super G Plus Module HFM 500. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product: SUPER-G® PLUS MODULES
  • Purpose: Ultrafiltration Multitube Modules for Juice Processing
  • Membrane Material: PVDF
  • Membrane Type: HFM-500 or HFM-513
  • Molecular Weight Cutoff:
    • HFM-500: 100,000 Daltons
    • HFM-513: 500,000 Daltons
    • (Note: Nominal separation range and retention characteristics are highly dependent on liquid and operating parameters; use as a guide only.)
  • Configuration: Nine (9) 1” diameter tubules in polysulfone shell
  • Applications: Juice processing for high recovery and high solids
  • Regulatory Information: Conforms with FDA regulations (CFR Title 21)
  • Options:
    • HFM-500 membrane for light juices
    • HFM-513 for all juices

Specifications

Part NumberModelMembrane Area ft² (m²)
0712301SUPER-G® PLUS 4310-HFM-50020.4 (1.9)
0712371SUPER-G® PLUS 4310-HFM-51320.4 (1.9)

Operating limits

  • Maximum Operating Pressure: 90 psi @ 120°F (6.2 bar @ 49°C)
  • Minimum Outlet Pressure: 10 psi (0.7 bar)
  • Maximum Permeate Pressure: 5 psi (0.3 bar)
  • Typical Feed Side Pressure Drop Per Module: 4-6 psi (0.27-0.40 bar)
  • Maximum Feed Side Pressure Drop Per Module: 6.6 psi @ 130°F (0.5 bar @ 54°C)
  • Maximum Operating Temperature at pH 8: 130°F (54°C)
  • Allowable pH Range at 120°F (49°C):
    • Continuous: 2.0 – 10.0
    • Short term: 1.5 – 10.5
  • Maximum Chlorine (cleaning): 200 ppm @ pH 10-10.5, 120°F (49°C)
  • (Note: Consult KMS Process Technology Group for specific applications.)

Mechanical / hydraulic

  • Overall dimensions: 6.5” (165 mm) x 110” (2794 mm)
  • Active length: 104” (2652 mm)
  • Diameter: 5.3” (136 mm) Ø
  • Sanitary connections: 1 1/2” and 4.3”