Summary

Product identification

Koch Membrane Systems (KMS) TARGA™ PM10 Hollow Fiber Cartridges are 8-inch industrial water ultrafiltration cartridges.

  • Model: TARGA™ 8072-367-43-PM10
  • Part Number: 0720415
  • Membrane Chemistry: Proprietary semi-permeable polysulfone
  • Membrane Type: PM10
  • Nominal MWCO: 10,000
  • Housing Shell/End Caps: Proprietary polysulfone
  • Fiber Support Netting: Polypropylene/Polyethylene
  • Permeate Collection Tube: PVC
  • Potting Material: Proprietary epoxy compound
  • Preservative: Glycerin
  • Regulatory Status: Classified by UL to NSF/ANSI Standard 61 and in accordance with NSF/ANSI Standard 372

Operating limits

  • Maximum Pressure (water): 45 psi (3.0 bar) @ 104º F (40º C) or less
  • Temperature Range: 32º F (0º C) - 104º F (40º C)
  • Maximum Production Transmembrane Pressure: 30 psi (2.1 bar)
  • Maximum Backflush Transmembrane Pressure: 20 psi (1.4 bar)
  • Maximum Total Chlorine @ 77º F (25º C) or lower: 200 ppm @ pH 9.5 or higher during backflush
  • Maximum Total Chlorine Contact: 200,000 ppm-hrs cumulative

Product water

  • Production Range: 11.0 (2.5 m³/hr) - 23.4 gpm (5.3 m³/hr)
    • Higher production can be expected for post IX/RO polishing applications.

Mechanical / hydraulic

  • Fiber Diameter (ID): 0.043 inch (1.1 mm)
  • Membrane Area: 367 ft² (34.1 m²)
  • Dimensions:
    • D (Diameter): 8.4 inches (213 mm)
    • L (Length): 72 inches (1829 mm)

Cartridge Storage Conditions

New cartridges are impregnated with glycerin and should be stored:

  • Indoors, out of direct sunlight.
  • At temperatures between 50 – 85 °F (10 – 30 °C).
  • At relative humidity below 70%.
  • In a horizontal position.

Used cartridges should be cleaned, rinsed, and impregnated before storage with one of the following solutions:

  • Glycerin @ 80 – 100% (best)
  • Phosphoric acid @ pH 2 – 3
  • Benzoic acid or sodium benzoate @ 1,000 ppm
  • Sodium bisulfite or sodium metabisulfite @ 1,000 – 5,000 ppm

Cartridges stored in sodium bisulfite or sodium metabisulfite should be flushed with clean water and impregnated with fresh solution at six-month intervals.

Cartridge Assembly and Components

ItemDescriptionKMS Part Number
18” HF CartridgeSee first page
2Leveling Hardware (Screw ½ ” X 13)1002443
3Leveling Hardware (Nut ½ “ X 13)1002443
48” Coupling Set (gasket included)0151303
5O-Ring, Permeate Adapter0211022
6Permeate Adapter1002655
72½” Coupling Set (gasket included)0151304 / 0151261
8End Cap0040213
  • Kit Process Pass for 8” cartridge: KMS Part Number: 0220158