Datasheet summary
Targa 8048-238-43-PM100 Hollow Fiber
Engineering summary from PDF text extraction for Targa 8048-238-43-PM100 Hollow Fiber. Verify every value with the OEM datasheet.
Summary
Product identification
TARGA™ PM100 Hollow Fiber Cartridges are 8-inch industrial water ultrafiltration cartridges.
- Membrane Chemistry: Proprietary semi-permeable polysulfone
- Membrane Type: PM100
- Housing Shell/End Caps: Proprietary polysulfone
- Fiber Support Netting: Polypropylene/Polyethylene
- Permeate Collection Tube: PVC
- Potting Material: Proprietary epoxy compound
- Regulatory Status: Classified by UL to NSF/ANSI Standard 61 and in accordance with NSF/ANSI Standard 372
- Storage Solution: Glycerin
| Model | Part Number | Nominal MWCO |
|---|---|---|
| TARGA™ 8048-238-43-PM100 | 0720406 | 100,000 |
| TARGA™ 8072-367-43-PM100 | 0720407 | 100,000 |
Operating limits
- Maximum Pressure (water): 45 psi (3.0 bar) @ 104º F (40º C) or less
- Temperature Range: 32º F (0º C) - 104º F (40º C)
- Maximum Production Transmembrane Pressure: 30 psi (2.1 bar)
- Maximum Backflush Transmembrane Pressure: 20 psi (1.4 bar)
- Maximum Total Chlorine @ 77º F (25º C) or lower: 200 ppm @ 9.5 pH or higher during intermittent backflush
- Maximum Total Chlorine Contact: 200,000 ppm-hrs cumulative
Product water
- Nominal MWCO: 100,000
- Production Range:
- TARGA™ 8048-238-43-PM100: 15.2 (3.4) - 7.1 (1.6) gpm (m³/hr)
- TARGA™ 8072-367-43-PM100: 23.4 (5.3) - 11.0 (2.5) gpm (m³/hr)
Mechanical / hydraulic
- Nominal Dimensions:
| Model | Fiber Diameter (ID) | Membrane Area | D | L |
|---|---|---|---|---|
| TARGA™ 8048-238-43-PM100 | 0.043 inch (1.1 mm) | 238 ft² (22.1 m²) | 8.4 (213) | 48 (1219) |
| TARGA™ 8072-367-43-PM100 | 0.043 inch (1.1 mm) | 367 ft² (34.1 m²) | 8.4 (213) | 72 (1829) |
- Cartridge Assembly and Components:
- 1 each 8” HF Cartridge (See first page)
- 2 each Leveling Hardware (Screw ½ ” X 13) (KMS Part Number: 1002443)
- 2 each Leveling Hardware (Nut ½ “ X 13) (KMS Part Number: 1002443)
- 2 each 8” Coupling Set (gasket included) (KMS Part Number: 0151303)
- 8 each O-Ring, Permeate Adapter (KMS Part Number: 0211022)
- 2 each Permeate Adapter (KMS Part Number: 1002655)
- 2 sets 2½” Coupling Set (gasket included) (KMS Part Number: 0151304 / 0151261)
- 2 each End Cap (KMS Part Number: 0040213)
- Kit Process Pass for 8” cartridge – KMS Part Number: 0220158
Storage conditions
- New cartridges:
- Impregnated with glycerin. Remove glycerin before initial use with a rinse, followed by a caustic wash and then a caustic/chlorine wash.
- Store in original shipping containers and crates until installation.
- Storage conditions:
- Indoors, out of direct sunlight.
- At temperatures between 50 – 85 °F (10 – 30 °C).
- At relative humidity below 70%.
- In a horizontal position.
- Used cartridges:
- Should be cleaned, rinsed, and impregnated before storage with one of the following solutions:
- Glycerin @ 80 – 100%
- Phosphoric acid @ pH 2 – 3
- Benzoic acid or sodium benzoate @ 1,000 ppm
- Sodium bisulfite or sodium metabisulfite @ 1,000 – 5,000 ppm
- Cartridges stored in sodium bisulfite or sodium metabisulfite should be flushed with clean water and impregnated with fresh solution at six-month intervals.
- Once impregnated, leave cartridges on the system with all valves closed or remove from the system and seal in plastic bags.
- Storage conditions for used cartridges are the same as for new cartridges.
- Cartridges must be drained, rinsed, and cleaned after storage per the pre-startup cleaning instruction sheet packed with each cartridge shipment.
- Should be cleaned, rinsed, and impregnated before storage with one of the following solutions:
Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.