Targa II 10048-35 Hollow Fiber

Engineering summary from PDF text extraction for Targa II 10048-35 Hollow Fiber. Verify every value with the OEM datasheet.

Summary

Product identification

The TARGA® II Hollow Fiber Cartridges are 10-inch water ultrafiltration cartridges.

  • Membrane Chemistry: Proprietary Semi-Permeable Polyethersulfone
  • Molecular Weight Cutoff: 100,000
  • Housing Shell: PVC
  • Fiber Support Netting: Polypropylene/Polyethylene
  • Permeate Collection Tube: PVC
  • Potting Material: Proprietary Compound
  • Membrane Construction: Hollow Fiber
  • Storage Solution: Glycerin/Water
  • Regulatory Status: Classified by UL to NSF/ANSI Standard 61 and in accordance with NSF/ANSI Standard 372

Product specifications

Part NumberModelFiber Diameter [inch (mm)]Membrane Area [ft² (m²)]Typical Production Range [gpm (m³/hr)]
0720708TARGA II 10048-350.035 (0.9)554 (51.5)15.4 - 32.2 (3.5 - 7.4)
0720709TARGA II 10072-350.035 (0.9)871 (80.9)24.2 - 51.4 (5.5 - 11.6)

Operating limits

  • Maximum Pressure (water): 45 psi (3.0 bar) @ 104°F (40°C) or less
  • Temperature Range: 32°F (0°C) - 104°F (40°C)
  • Maximum Production Transmembrane Pressure: 30 psi (2.1 bar)
  • Maximum Backflush Transmembrane Pressure: 25 psi (1.7 bar)
  • Allowable pH Range: 1.5 - 13
  • Maximum Total Chlorine @ 77°F (25°C) or lower: 500 ppm @ pH >10
  • Typical Cleaning Total Chlorine @ 77°F (25°C) or lower: 200 ppm @ pH >10
  • Maximum Backflush Total Chlorine @ 77°F (25°C) or lower: 50 ppm @ pH >9

Mechanical / hydraulic

Nominal Dimensions

ModelFiber Diameter (ID) [Inches (mm)]D [Inches (mm)]L [Inches (mm)]
TARGA II 10048-350.035 inch (0.9 mm)10.75 (273)48 (1219)
TARGA II 10072-350.035 inch (0.9 mm)10.75 (273)72 (1829)

Dimensions are provided for reference only and should not be interpreted as accurate specifications.

Components

The following components are required for cartridge assembly:

ItemDescriptionRequired for Single Permeate RemovalRequired for Dual Permeate Removal
110” HF Cartridge1 each1 each
210” HF SS Coupling2 each2 each
310” HF Face Seal2 each2 each
410” HF K-Ring2 each2 each
5Permeate O-rings4 each4 each
610” Plastic HF End Cap W Port1 each2 each
710” Plastic HF End Cap W/O Port1 each0 each
810” HF End Cartridge Support2 each2 each
910” HF Cartridge Support Hardware2 each2 each
102” Groove-End Coupling3 each4 each

Storage

New Cartridge Storage Conditions: New cartridges are packaged in a glycerin/water solution. Prior to installation, cartridges should be stored in their original packaging under the following conditions:

  • Indoors, out of direct sunlight.
  • Temperatures between 50–85°F (10–30°C).
  • Relative humidity below 70%.
  • In a horizontal position. It is recommended to use new cartridges within one year of shipment.

Used Cartridge Storage Conditions: Used cartridges should be cleaned, rinsed, and impregnated before storage with one of the following solutions:

  • Glycerin @ 80–100%
  • Phosphoric acid @ pH 2–3
  • Benzoic acid or sodium benzoate @ 1,000 ppm
  • Sodium bisulfite or sodium metabisulfite @ 1,000–5,000 ppm Cartridges stored in sodium bisulfite or sodium metabisulfite require flushing with clean water and impregnation with fresh solution at six-month intervals. Once impregnated, cartridges should be left on the system with all valves closed or removed and sealed in plastic bags. Storage conditions for used cartridges are the same as for new cartridges.