Datasheet summary
Targa II 8048-35 Hollow Fiber
Engineering summary from PDF text extraction for Targa II 8048-35 Hollow Fiber. Verify every value with the OEM datasheet.
Summary
Product Identification
TARGA® II HOLLOW FIBER CARTRIDGES are 8-inch Water Ultrafiltration Cartridges.
- Membrane Chemistry: Proprietary Semi-Permeable Polyethersulfone
- Molecular Weight Cutoff: 100,000
- Housing Shell/End Caps: Proprietary Polysulfone
- Fiber Support Netting: Polypropylene/Polyethylene
- Permeate Collection Tube: PVC
- Potting Material: Proprietary Compound
- Membrane Construction: Hollow Fiber
- Storage Solution: Glycerin
- Regulatory Status: Classified by UL to NSF/ANSI Standard 61 and in accordance with NSF/ANSI Standard 372
Product Specifications
| Part Number | Model | Fiber Diameter [Inch (mm)] | Membrane Area [ft² (m²)] | Production Range [gpm (m³/hr)] |
|---|---|---|---|---|
| 0720425 | TARGA II 8048-35 | 0.035 (0.9) | 346 (32.1) | 9.6 - 20.4 (2.2 - 4.6) |
| 0720426 | TARGA II 8072-35 | 0.035 (0.9) | 544 (50.5) | 15.1 - 32.1 (3.4 - 7.3) |
| 0720427 | TARGA II 8H072-35 | 0.035 (0.9) | 544 (50.5) | 15.1 - 32.1 (3.4 - 7.3) |
Operating Limits
- Maximum Pressure (water): 45 psi (3.0 bar) @ 104°F (40°C) or less
- Temperature Range: 32°F (0°C) - 104°F (40°C)
- Maximum Production Transmembrane Pressure: 30 psi (2.1 bar)
- Maximum Backflush Transmembrane Pressure: 25 psi (1.4 bar)
- Allowable pH Range: 1.5 - 13
- Maximum Total Chlorine @ 77°F (25°C) or lower: 500 ppm @ pH >10
- Recommended Total Chlorine @ 77°F (25°C) or lower: 200 ppm @ pH >10
- Maximum Backflush Total Chlorine @ 77°F (25°C) or lower: 50 ppm @ pH >9
Mechanical / Hydraulic
Nominal Dimensions
| Model | Fiber Diameter (ID) | D Inches (mm) | L Inches (mm) |
|---|---|---|---|
| TARGA II 8048-35 | 0.035 inch (0.9 mm) | 8.4 (213) | 48 (1219) |
| TARGA II 8072-35 | 0.035 inch (0.9 mm) | 8.4 (213) | 72 (1829) |
| TARGA II 8H072-35 | 0.035 inch (0.9 mm) | 8.4 (213) | 72 (1829) |
Dimensions are provided for reference only and should not be interpreted as accurate specifications.
Cartridge Assembly and Components
- 8” HF Cartridge: 1 each
- Leveling Hardware (Screw ½” X 13): 2 each
- Leveling Hardware (Nut ½“ X 13): 2 each
- 8” Coupling Set (gasket included): 2 each
- O-Ring, Permeate Adapter: 8 each
- Permeate Adapter: 2 each
- 2.5” Coupling Set (gasket included): 2 sets
- End Cap: 2 each
- Process Pass Kit for 8” cartridge – KMS Part Number 0220158
Storage Conditions
New Cartridges
New cartridges are packaged in a glycerin/water solution. Before initial use, this solution should be removed with a water rinse, followed by a caustic wash, and then a caustic/chlorine wash.
Prior to installation, cartridges should be stored in their original packaging under the following conditions:
- Indoors, out of direct sunlight.
- Temperatures between 50 – 85°F (10 – 30°C).
- Relative humidity below 70%.
- In a horizontal position.
It is recommended to use new cartridges within one year of shipment. For longer-term storage, consult KMS.
Used Cartridges
Used cartridges should be cleaned, rinsed, and impregnated before storage with one of the following solutions:
- Glycerin @ 80 – 100% (best)
- Phosphoric acid @ pH 2 – 3
- Benzoic acid or sodium benzoate @ 1,000 ppm
- Sodium bisulfite or sodium metabisulfite @ 1,000 – 5,000 ppm
Cartridges stored in sodium bisulfite or sodium metabisulfite should be flushed with clean water and impregnated with fresh solution at six-month intervals. Once impregnated, cartridges should be left on the system with all valves closed or removed from the system and sealed in plastic bags. Storage conditions described for new cartridges (indoors, temperature, humidity, horizontal) also apply to used cartridges. Cartridges must be drained, rinsed, and cleaned after storage per the pre-startup cleaning instruction sheet.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.