Summary

Product identification

AQUADYN UA1060-HP Hollow Fiber UF Modules feature a 0.025-micron pore size Polyacrylonitrile (PAN) hollow fiber membrane potted in a U-shaped arrangement. These modules are suitable for treating oily wastewaters and can be a direct replacement for the AQUADYN UA1060 module.

  • Membrane Polymer: Polyacrylonitrile (PAN)
  • Nominal Pore Size: 0.025 µm
  • Membrane Type: Hollow Fiber
  • Hollow Fiber Diameter OD/ID: 1.7 mm / 0.9 mm (0.067 inch / 0.035 inch)
  • Housing Material: uPVC
  • Membrane Potting: Epoxy
  • Filtration Flow Path: Out → In
  • Operating Mode: Dead-End (Preferred) / Cross-Flow (Optional)
  • Preservative: Sodium meta-bisulfite / Glycerin
  • Nominal Membrane Area: 65 m² (700 ft²)

Operating limits

  • Filtrate Flow Range: 0.65 – 7.2 m³/h (2.7 – 29.9 gpm)
  • Maximum Feed Pressure (at 20°C / 68°F): 5.0 bar (72.5 psi)
  • Maximum Feed Pressure (at 45°C / 113°F): 2.0 bar (29.0 psi)
  • Maximum Transmembrane Pressure: 2.0 bar (29.0 psi)
  • Maximum Backflush Flowrate: 10.4 m³/h (43.2 gpm)
  • Typical Air Scour Rate: 5.0 - 10.0 Nm³/h (3.0 - 5.9 scfm)
  • Maximum Air Scour Pressure: 0.8 bar (11.6 psi)
  • pH Range for Operation: 2.0 – 10.0
  • Temperature Range: 5 – 45°C (41 – 113°F)

Cleaning parameters

  • pH Range: 1.0 – 10.0
  • Max. Temperature: 45°C (113°F)
  • Max. Active Chlorine Concentration: 100 ppm
  • Max. Active Chlorine Exposure: 100,000 ppm-hours
  • Max. Hydrogen Peroxide Concentration: 500 ppm
  • Max. Hydrogen Peroxide Exposure: 500,000 ppm-hours

Mechanical / hydraulic

  • Dry Weight (Shipping): 48 kg (105.8 lb)
  • Module Diameter: 273 mm (10.7 in)
  • Module Length: 1737 mm (68.4 in)
  • Feed Port: 2” Victaulic
  • Reject Port: 2” Victaulic
  • Permeate Port: 2” Victaulic
  • Air Inlet Port: G 1/2”