Datasheet summary
UA1060
Engineering summary from PDF text extraction for UA1060. Verify every value with the OEM datasheet.
Summary
Product identification
AQUADYN UA1060-HP Hollow Fiber UF Modules feature a 0.025-micron pore size Polyacrylonitrile (PAN) hollow fiber membrane potted in a U-shaped arrangement. These modules are suitable for treating oily wastewaters and can be a direct replacement for the AQUADYN UA1060 module.
- Membrane Polymer: Polyacrylonitrile (PAN)
- Nominal Pore Size: 0.025 µm
- Membrane Type: Hollow Fiber
- Hollow Fiber Diameter OD/ID: 1.7 mm / 0.9 mm (0.067 inch / 0.035 inch)
- Housing Material: uPVC
- Membrane Potting: Epoxy
- Filtration Flow Path: Out → In
- Operating Mode: Dead-End (Preferred) / Cross-Flow (Optional)
- Preservative: Sodium meta-bisulfite / Glycerin
- Nominal Membrane Area: 65 m² (700 ft²)
Operating limits
- Filtrate Flow Range: 0.65 – 7.2 m³/h (2.7 – 29.9 gpm)
- Maximum Feed Pressure (at 20°C / 68°F): 5.0 bar (72.5 psi)
- Maximum Feed Pressure (at 45°C / 113°F): 2.0 bar (29.0 psi)
- Maximum Transmembrane Pressure: 2.0 bar (29.0 psi)
- Maximum Backflush Flowrate: 10.4 m³/h (43.2 gpm)
- Typical Air Scour Rate: 5.0 - 10.0 Nm³/h (3.0 - 5.9 scfm)
- Maximum Air Scour Pressure: 0.8 bar (11.6 psi)
- pH Range for Operation: 2.0 – 10.0
- Temperature Range: 5 – 45°C (41 – 113°F)
Cleaning parameters
- pH Range: 1.0 – 10.0
- Max. Temperature: 45°C (113°F)
- Max. Active Chlorine Concentration: 100 ppm
- Max. Active Chlorine Exposure: 100,000 ppm-hours
- Max. Hydrogen Peroxide Concentration: 500 ppm
- Max. Hydrogen Peroxide Exposure: 500,000 ppm-hours
Mechanical / hydraulic
- Dry Weight (Shipping): 48 kg (105.8 lb)
- Module Diameter: 273 mm (10.7 in)
- Module Length: 1737 mm (68.4 in)
- Feed Port: 2” Victaulic
- Reject Port: 2” Victaulic
- Permeate Port: 2” Victaulic
- Air Inlet Port: G 1/2”
Important information
AQUADYN UA1060-HP modules must be handled and stored appropriately to ensure proper operation and to prevent membrane damage. They must be installed correctly before start-up and cleaned routinely via backwash. For detailed information, refer to the Operation Manual.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.