Summary
Product Identification
The TRISEP® DS Food & Dairy UP005XT series elements feature a NADIR® UP005 polyethersulfone (PES) membrane, cast on a polypropylene support material. These elements are designed for cleaning at high temperature and high pH conditions. The membrane has a nominal 5,000 Da molecular weight cut-off, offering high protein rejection. In field studies, the UP005 membrane reportedly showed as much as 75% less protein passage than competitive membranes.
TRISEP DS elements are built with FDA compliant materials, comply with European food regulations (EU 10/2011 and EC 1935/2004), and meet USDA standards. They also conform to USDA 3A sanitary standard 45-03 and have Halal and Kosher certifications.
The elements are available with different feed spacers and in common industry sizes. All models on this datasheet have a netting outer wrap and diamond-shaped feed spacers.
Available Models & Design Information:
- TRISEP® DS UP005XT 3838-31
- Membrane Area: 7.0 m² (75 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® DS UP005XT 3838-46
- Membrane Area: 5.7 m² (61 ft²)
- Feed Spacer Thickness: 46 mil
- TRISEP® DS UP005XT 3838-65
- Membrane Area: 4.5 m² (48 ft²)
- Feed Spacer Thickness: 65 mil
- TRISEP® DS UP005XT 3838-80
- Membrane Area: 4.0 m² (43 ft²)
- Feed Spacer Thickness: 80 mil
- TRISEP® DS UP005XT 6338-31
- Membrane Area: 20.5 m² (221 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® DS UP005XT 6338-46
- Membrane Area: 17.1 m² (184 ft²)
- Feed Spacer Thickness: 46 mil
- TRISEP® DS UP005XT 6338-65
- Membrane Area: 12.9 m² (139 ft²)
- Feed Spacer Thickness: 65 mil
- TRISEP® DS UP005XT 6338-80
- Membrane Area: 11.5 m² (124 ft²)
- Feed Spacer Thickness: 80 mil
- TRISEP® DS UP005XT 6438-31
- Membrane Area: 20.5 m² (221 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® DS UP005XT 6438-46
- Membrane Area: 17.1 m² (184 ft²)
- Feed Spacer Thickness: 46 mil
- TRISEP® DS UP005XT 6438-65
- Membrne Area: 12.9 m² (139 ft²)
- Feed Spacer Thickness: 65 mil
- TRISEP® DS UP005XT 6438-80
- Membrane Area: 11.5 m² (124 ft²)
- Feed Spacer Thickness: 80 mil
- TRISEP® DS UP005XT 8038-31
- Membrane Area: 32.0 m² (344 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® DS UP005XT 8038-46
- Membrane Area: 25.0 m² (269 ft²)
- Feed Spacer Thickness: 46 mil
- TRISEP® DS UP005XT 8038-65
- Membrane Area: 21.0 m² (226 ft²)
- Feed Spacer Thickness: 65 mil
- TRISEP® DS UP005XT 8038-80
- Membrane Area: 18.0 m² (194 ft²)
- Feed Spacer Thickness: 80 mil
- TRISEP® DS UP005XT 8338-31
- Membrane Area: 34.0 m² (366 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® DS UP005XT 8338-46
- Membrane Area: 27.5 m² (296 ft²)
- Feed Spacer Thickness: 46 mil
- TRISEP® DS UP005XT 8338-65
- Membrane Area: 23.5 m² (253 ft²)
- Feed Spacer Thickness: 65 mil
- TRISEP® DS UP005XT 8338-80
- Membrane Area: 21.2 m² (228 ft²)
- Feed Spacer Thickness: 80 mil
Operating Limits
- Maximum Operating Pressure: 10 bar (145 psi)
- Maximum Operating Temperature: 60°C (140°F)
- Maximum Cleaning Temperature: 75°C (167°F)
- Maximum Sanitization Temperature: 85°C (185°F) at 1.7 bar max pressure, pH 6.0 – 8.0
- Cleaning pH Range: 1.0 – 13.0
- Cleaning Chlorine Tolerance: 200 ppm for sanitization at pH ≥ 10.5
- Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing
Mechanical / Hydraulic
Physical Dimensions:
- TRISEP® DS UP005XT 3838-31
- Element Weight: 4 kg (9 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 96 mm (3.8 inches)
- Dim. C (Inner Diameter): 21.1 mm (0.83 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 3838-46
- Element Weight: 4 kg (9 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 96 mm (3.8 inches)
- Dim. C (Inner Diameter): 21.1 mm (0.83 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 3838-65
- Element Weight: 4 kg (9 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 96 mm (3.8 inches)
- Dim. C (Inner Diameter): 21.1 mm (0.83 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 3838-80
- Element Weight: 4 kg (9 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 96 mm (3.8 inches)
- Dim. C (Inner Diameter): 21.1 mm (0.83 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6338-31
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6338-46
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6338-65
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6338-80
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6438-31
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6438-46
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6438-65
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 6438-80
- Element Weight: 11 kg (24 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 162 mm (6.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8038-31
- Element Weight: 16 kg (36 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 201 mm (7.9 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8038-46
- Element Weight: 16 kg (36 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 201 mm (7.9 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8038-65
- Element Weight: 16 kg (36 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 201 mm (7.9 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8038-80
- Element Weight: 16 kg (36 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 201 mm (7.9 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8338-31
- Element Weight: 18 kg (40 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 211 mm (8.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8338-46
- Element Weight: 18 kg (40 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 211 mm (8.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8338-65
- Element Weight: 18 kg (40 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 211 mm (8.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
- TRISEP® DS UP005XT 8338-80
- Element Weight: 18 kg (40 lb)
- Dim. A: 965 mm (38.0 inches)
- Dim. B: 211 mm (8.3 inches)
- Dim. C (Inner Diameter): 28.9 mm (1.138 inches)
- Permeate Tube: Female
Important Information
- Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate during the flush prior to operation. For a detailed procedure, refer to the "Element Start-Up Guide – System Start-Up (TSG-O-005)".
- Cleaning: Elements require periodic cleaning to ensure proper operation and prevent membrane damage. Refer to the "Membrane Cleaning Guide – Food & Dairy: UF & MF Elements (TSG-C-004)".
- Storage: Proper storage is necessary to ensure correct operation and prevent membrane damage. Refer to the "Element Storage Guides (TSG-O-009 & TSG-O-010)".
MANN+HUMMEL Water & Fluid Solutions also offers a range of customizable specialty elements for challenging water and process applications, including low-fouling RO, submerged UF, continuous high temperature, ultra-high pressure, and unique sanitary designs.