Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

UE1060

Engineering summary from PDF text extraction for UE1060. Verify every value with the OEM datasheet.

Summary

Product identification

The AQUADYN® UE1060-HP is a hollow fiber ultrafiltration (UF) module. It features a Polyethersulfone (PES) hollow fiber membrane with a 0.025-micron pore size, designed to produce high-quality filtrate. The module can be used for a wide range of applications treating various feed waters, including sea, surface, and well water. This module can be used as a direct replacement for the AQUADYN® UE1060 module.

Membrane characteristics

  • Membrane Polymer: Polyethersulfone (PES)
  • Nominal Pore Size: 0.025 µm
  • Membrane Type: Hollow Fiber
  • Hollow Fiber Diameter OD/ID: 1.55 mm / 0.95 mm (0.061 inch/ 0.037 inch)

Module specifications

  • Housing Material: uPVC
  • Membrane Potting: Epoxy
  • Filtration Flow Path: Out → In
  • Operating Mode: Dead-End (Preferred) / Cross-Flow (Optional)
  • Preservative: Ethanol + Glycerin
  • Nominal Membrane Area: 55 m² (592 ft²)

Operating limits

  • Max. Water Flow: 1.6 – 6.6 m³/h (7.3 – 29.1 gpm)
  • Maximum Feed Pressure (at 20°C / 68°F): 5.0 bar (72.5 psi)
  • Maximum Feed Pressure (at 45°C / 113°F): 2.0 bar (29.0 psi)
  • Maximum Transmembrane Pressure: 1 bar (14.5 psi)
  • Maximum Backflush Flow: 13.2 m³/h (58.1 gpm)
  • Typical Air Scour Rate: 10 Nm³/h (5.9 scfm)
  • Maximum Air Scour Pressure: 0.6 bar (8.7 psi)
  • pH Range for Operation: 2.0 – 12.0
  • Temperature Range: 5 – 45°C (41 – 113°F)

Cleaning parameters

  • pH Range: 1.0 – 13.0
  • Max. Temperature: 45°C (113°F)
  • Max. Active Chlorine Concentration: 200 ppm
  • Max. Active Chlorine Exposure: 200,000 ppm-hours

Mechanical / hydraulic

  • Dry Weight: 41 kg (90.4 lb)
  • Module Diameter: 273 mm (10.7 in)
  • Module Length: 1737 mm (68.4 in)
  • Feed Port: 2” Victaulic
  • Reject Port: 2” Victaulic
  • Permeate Port: 2” Victaulic
  • Air Inlet Port: G 1/2”

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data should always match the official OEM PDF revision used on the project.