Datasheet summary
MD 063 CP 2N
Engineering summary from PDF text extraction for MD 063 CP 2N. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: MICRODYN MD 063 CP 2N
- Product Type: Capillary Microfiltration Modules
- Date: 09/15/2021
- Membrane Type: Highly porous symmetrical polypropylene (PP) membrane
- Key Features: Modern filtration method for separation of suspended particles or emulsified liquids; available in 0.1- and 0.2-micron options with a very narrow pore size distribution; very resistant to abrasion and mechanical damage due to homogeneous construction; unmatched chemical resistance and pH resistance (0 – 14) due to polypropylene membrane material.
Membrane Characteristics
- Membrane Polymer: Polypropylene (PP)
- Inner Diameter: 1.8 mm (0.07 inches)
- Nominal Pore Size: 0.2 µm
Module Specifications
- Housing Material: Polypropylene (PP)
- Sealing Material: EPDM
- Potting Material: Polyurethane (PU)
- Number of Capillaries: 200
- Nominal Membrane Area: 0.75 m² (8.1 ft²)
- Free Flow Area: 5.0 cm² (0.8 in²)
Operating Limits
- Temperature Range: 5 – 40 °C (41 – 104 °F)
- Maximum TMP inside to outside:
- 1.6 bar (23.2 psi) at 25 °C (77 °F)
- 1.4 bar (20.3 psi) at 40 °C (104 °F)
- Maximum Backpulse Pressure above Outlet Pressure:
- 1.0 bar (14.5 psi) at 25 °C (77 °F)
- 0.5 bar (7.3 psi) at 40 °C (104 °F)
- Feed Flow Rate at Axial Velocity of 1 m/s: 1,440 l/h (6.3 GPM)
- Housing Maximum Pressure: 3.0 bar (43.5 psi)
Mechanical / hydraulic
- Length: 750 mm (29.5 in)
- Connection for Permeate: Screw connection R1¼’’, DIN 2999
- Connection for Concentrate: Screw connection R2¾’’, DIN 2999
Important Information
- Storage & Handling: MICRODYN Capillary Modules must be handled and stored appropriately to ensure proper operation and prevent membrane damage. Refer to "MICRODYN MF Modules – Technical Manual" and "MICRODYN MF Modules – Handling Instructions".
- Chemical Cleaning: To obtain a high filtration capacity on a long-term basis, chemical cleaning of MICRODYN Capillary Modules is required at times. Refer to "MICRODYN MF Modules – Chemical Cleaning of MICRODYN Modules" and "MICRODYN MF Modules – Handling Instructions".
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data should always match the OEM PDF revision used on the project.