Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

MD 150 CU 2N

Engineering summary from PDF text extraction for MD 150 CU 2N. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: MICRODYN MD 150 CU 2M Capillary Microfiltration Module
  • Date: 09/15/2021

MICRODYN capillary microfiltration modules utilize a modern filtration method for the separation of suspended particles or emulsified liquids. The highly porous symmetrical structure of the MICRODYN polypropylene membrane ensures high permeability rates. The membrane is available in 0.1- and 0.2-micron options, offering a very narrow pore size distribution for sharp separations. Its homogeneous construction provides strong resistance to abrasion and mechanical damage. The polypropylene membrane material also offers unmatched chemical and pH resistance (0–14).

Membrane Characteristics

  • Membrane Polymer: Polypropylene (PP)
  • Inner Diameter: 1.8 mm (0.1 inches)
  • Nominal Pore Size: 0.2 µm

Module Specifications

  • Housing Material: Polysulfone (PS)
  • Potting Material: Polyurethane (PU)
  • Number of Capillaries: 1800
  • Nominal Membrane Area: 6.3 m² (68 ft²)
  • Free Flow Area: 46 cm² (7.1 in²)

Operating limits

  • Temperature Range: 5 – 40 °C (41 – 104 °F)
  • Maximum TMP inside to outside (at 25 °C): 2.2 bar (32 psi)
  • Maximum TMP inside to outside (at 40 °C): 2.2 bar (32 psi)
  • Maximum Backpulse Pressure above Outlet Pressure (at 25 °C): 1.0 bar (14.5 psi)
  • Maximum Backpulse Pressure above Outlet Pressure (at 40 °C): 0.5 bar (7.3 psi)
  • Feed Flow Rate at Axial Velocity of 1 m/s: 16,400 l/h (72 GPM)
  • Housing Maximum Pressure: 3.0 bar (43.5 psi)

Mechanical / hydraulic

  • Length: 750 mm (29.5 in)
  • Diameter: 165 mm (6.5 in)
  • Connection for Permeate: Cone flange R 1 ½”
  • Connection for Concentrate: Cone flange R 1 ½”

Important Information

For proper operation, handling, and chemical cleaning procedures, please refer to the following manufacturer documents: "MICRODYN MF Modules – Technical Manual," "MICRODYN MF Modules – Handling Instructions," and "MICRODYN MF Modules – Chemical Cleaning of MICRODYN Modules."


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions found in the official PDF datasheet. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.