Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

RO HRLE

Engineering summary from PDF text extraction for RO HRLE. Verify every value with the OEM datasheet.

Summary

Product identification

The MICRODYN RO HRLE series consists of High Rejection, Low Energy Brackish Water RO Elements. These membranes are designed for water purification applications requiring high rejection combined with reduced energy consumption, operating at low pressure conditions. They feature Thin-Film Composite Polyamide membrane chemistry.

Membrane characteristics

  • Membrane Chemistry: Thin-Film Composite Polyamide
  • Stabilized Salt Rejection (%): 99.5
  • Minimum Salt Rejection (%): 99.3

Element Specifications

ModelPermeate Flow - m³/day (GPD)Membrane Area - m² (ft²)
4040-HRLE7.9 (2,100)7.9 (85)
8040-HRLE-40039.7 (10,500)37.2 (400)
8040-HRLE-400/3439.7 (10,500)37.2 (400)
8040-HRLE-44043.5 (11,500)40.9 (440)
  • Permeate flow rates are tested under conditions of 1,500 ppm NaCl, 10.3 bar (150 psi), 25°C (77°F), 15% recovery, pH 8.0, and 30 minutes operation. Flow rates will be no more than 15% below the values shown.
  • All models on this sheet have diamond shaped feed spacers.

Physical Dimensions

ModelDim. A – mm (inches)Dim. B – mm (inches)Dim. C – mm (inches)Permeate TubeOuterwrap TypeElement Weight – kg (lb)
4040-HRLE1,016 (40.0)99 (3.9)19.1 (0.75)MaleTape4 (9)
8040-HRLE-4001,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass16 (36)
8040-HRLE-400/341,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass16 (36)
8040-HRLE-4401,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass17 (37)
  • Dimension "C" is the Inner Diameter for Female elements and the Outer Diameter for Male elements.
  • Male elements have a protruding permeate tube with Dimension "D" of 26.7 mm (1.05 inches).

Operating limits

  • Maximum Operating Pressure:
    • Tape Outerwrap Models: 21 bar (300 psi)
    • Fiberglass Outerwrap Models: 41 bar (600 psi)
  • Maximum Operating Temperature: 45°C (113°F)
  • Cleaning pH Range: 1.0 – 12.0
  • Chlorine Tolerance: < 0.1 ppm (Pretreatment is recommended for the removal of free chlorine and other oxidizing agents).
  • Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing
  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Important Information

  • Start-up: MANN+HUMMEL Water & Fluid Solutions recommends flushing elements for 30 minutes at low pressure and discarding permeate during the flush prior to operation.
  • Cleaning: MICRODYN RO membrane elements must be cleaned periodically to ensure proper operation and to prevent membrane damage. Refer to the Membrane Cleaning Guide (TSG-C-001).
  • Storage: MICRODYN RO membrane elements must be stored appropriately to ensure proper operation and to prevent membrane damage. Refer to Element Storage Guides (TSG-O-009 & TSG-O-010).

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must always match the OEM PDF revision used on the project.