RO LE

Engineering summary from PDF text extraction for RO LE. Verify every value with the OEM datasheet.

Summary

Product identification

The MICRODYN RO LE series consists of Low Energy Brackish Water Reverse Osmosis (RO) Elements designed for water purification applications requiring reduced energy consumption. These elements feature a low energy membrane for upgrading RO systems and operate under low pressure conditions. They are certified to NSF/ANSI Standard 61 for use in drinking water systems.

MICRODYN RO elements are available in standard 4-inch and 8-inch spiral-wound designs.

  • Membrane Chemistry: Thin-Film Composite Polyamide
  • Construction: Spiral-Wound Membrane Element with Fiberglass Outerwrap (some models use Tape Outerwrap)
  • Stabilized Salt Rejection: 99.3%
  • Minimum Salt Rejection: 98.8%

All models on this sheet have diamond shaped feed spacers.

Element Specifications

Test conditions for permeate flow: 1,500 ppm NaCl, 10.3 bar (150 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown.

ModelPermeate Flow - m³/day (GPD)Membrane Area - m² (ft²)
4040-LE8.3 (2,200)7.9 (85)
8040-LE-40040.0 (10,550)37.2 (400)
8040-LE-400/3440.0 (10,550)37.2 (400)
8040-LE-44043.9 (11,550)40.9 (440)

Mechanical / Hydraulic

The physical dimensions for the elements are as follows:

ModelDim. A – mm (inches)Dim. B – mm (inches)Dim. C – mm (inches)Permeate TubeOuterwrap TypeElement Weight – kg (lb)
4040-LE1,016 (40.0)99 (3.9)19.1 (0.75)MaleTape4 (9)
8040-LE-4001,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass16 (36)
8040-LE-400/341,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass16 (36)
8040-LE-4401,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass17 (37)
  • For Female elements, Dimension “C” is the Inner Diameter. For Male elements, “C” is the Outer Diameter.
  • Male elements have a protruding permeate tube. Dimension “D” (not in table, but referenced in diagram description) is 26.7 mm (1.05 in).
  • Element shipping weight depends on packaging material and quantity.

Operating limits

  • Maximum Operating Pressure:
    • Tape Outerwrap Models: 21 bar (300 psi)
    • Fiberglass Outerwrap Models: 41 bar (600 psi)
  • Maximum Operating Temperature: 45°C (113°F)
  • Cleaning pH Range: 1.0 – 12.0
  • Chlorine Tolerance: < 0.1 ppm (Pretreatment is recommended for the removal of free chlorine and other oxidizing agents.)
  • Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing
  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Important Information

  • Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate during the flush prior to operation.
  • Cleaning: MICRODYN RO membrane elements must be cleaned periodically to ensure proper operation.
  • Storage: Elements must be stored appropriately to ensure proper operation.
  • Regulatory: All models on this sheet are certified to NSF/ANSI Standard 61 for use in drinking water systems.