Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

RO XRLE

Engineering summary from PDF text extraction for RO XRLE. Verify every value with the OEM datasheet.

Summary

Product Identification

The MICRODYN RO XRLE series consists of high rejection, low energy brackish water reverse osmosis (RO) elements. These spiral-wound membranes are designed for water purification applications requiring high rejection combined with reduced energy consumption, operating at low pressure. NSF certification is available upon request.

  • Membrane Chemistry: Thin-Film Composite Polyamide

The following table details the specifications for various models:

ModelPermeate Flow – m³⁄day (GPD)Membrane Area – m² (ft²)
4040-XRLE7.2 (1,900)7.9 (85)
8040-XRLE-40035.9 (9,500)37.2 (400)
8040-XRLE-400/3435.9 (9,500)37.2 (400)
8040-XRLE-44039.7 (10,500)40.9 (440)

Performance is tested under the following conditions: 1,500 ppm NaCl, 10.3 bar (150 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown. All models use diamond-shaped feed spacers.

Product Water

  • Stabilized Salt Rejection: 99.65%
  • Minimum Salt Rejection: 99.40%

Operating Limits

  • Maximum Operating Pressure:
    • Tape Outerwrap Models: 21 bar (300 psi)
    • Fiberglass Outerwrap Models: 41 bar (600 psi)
  • Maximum Operating Temperature: 45°C (113°F)
  • Cleaning pH Range: 1.0 – 12.0
  • Chlorine Tolerance: < 0.1 ppm
  • Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing

Feed Water

  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Mechanical / Hydraulic

The physical dimensions for the elements are as follows:

ModelDim. A – mm (inches)Dim. B – mm (inches)Dim. C – mm (inches)Permeate TubeOuterwrap TypeElement Weight – kg (lb)
4040-XRLE1,016 (40.0)99 (3.9)19.1 (0.75)MaleTape4 (9)
8040-XRLE-4001,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass16 (36)
8040-XRLE-400/341,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass16 (36)
8040-XRLE-4401,016 (40.0)201 (7.9)28.6 (1.125)FemaleFiberglass17 (37)

Note on Dimension "C": For Female elements, "C" is the Inner Diameter. For Male elements, "C" is the Outer Diameter. Male elements also have a protruding permeate tube ("D" in diagram) with a dimension of 26.7 mm (1.05 in).

Important Information

Refer to the official MANN+HUMMEL Water & Fluid Solutions guides for detailed start-up, cleaning, and storage procedures to ensure proper operation and prevent membrane damage. Pretreatment is recommended for the removal of free chlorine and other oxidizing agents to prevent damage to membranes.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.