Datasheet summary
UP005 P
Engineering summary from PDF text extraction for UP005 P. Verify every value with the OEM datasheet.
Summary
Product Identification
The NADIR® UP005 P is an Ultrafiltration (UF) membrane. It is a polyethersulfone (PES) flat sheet membrane with a nominal molecular weight cut-off (M.W.C.O.) of 5,000 Daltons. It is FDA compliant.
Membrane Characteristics
- Membrane Chemistry: Polyethersulfone (PES)
- Backing Material: Polypropylene
- Nominal M.W.C.O.: 5,000 Daltons
- Thickness: 210 – 250 µm
Operating Limits
- pH Range: 0.0 – 14.0
- Chlorine Tolerance (sanitization): 200 ppm at pH ≥ 10.5
- Daily Short-Term Cleaning: Maximum 50°C (125°F) for 30 minutes.
Mechanical / Hydraulic
- Permeability: ≥ 10.0 LMH/bar (≥ 0.4 GFD/psi)
- Test conditions for permeability: Clean water, 4 bar (58 psi), 20°C (68°F), crossflow operation.
General Information
The UP005 flat sheet membrane is designed for use in food, dairy, process separations, and water purification applications, offering high protein rejection.
Standard Sizes:
- A4 Sample Size: 210 mm x 297 mm (8.27 in x 11.69 in)
- Nominal Roll Size: 150 m x 1016 mm (492 ft x 40.0 in) Custom lengths may be available.
Initial Flush: It is recommended to flush the membrane for 30 minutes prior to operation, discarding the permeate during this flush.
Storage: Membranes shipped dry should be stored in a cool, dry place, away from direct sunlight. Refer to the Membrane Storage Guide – Flat Sheet Membrane (TSG-O-011) for more details.
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.