Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

4611

Engineering summary from PDF text extraction for 4611. Verify every value with the OEM datasheet.

Summary

Product identification

These are 4.6” brackish water Reverse Osmosis (RO) elements, part of the Oltremare series, designed for water purification applications including sanitary and drinking water. They are available as wet or dry products for convenience.

Membrane Characteristics

  • Membrane: RO
  • Membrane Type: Polyamide
  • Stabilized Salt Rejection (%):
    • BR1HR: 99
    • LOW1: 99
  • Minimum Salt Rejection (%):
    • BR1HR: 98
    • LOW1: 98

Design Information

ModelPermeate Flow (m³/day (gpd))Maximum Feed Flow (m³/h (gpm))Membrane Area (m² (ft²))
Oltremare BR1HR-4611E4.9 (1300)3 (13)2.9 (31)
Oltremare LOW1– 4611E3.5 (900)3 (13)2.9 (31)

Test conditions for BR1HR-4611E: 1,500 ppm NaCl, 15.5 bar (225 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates may be up to 15% below shown values. Test conditions for LOW1– 4611E: 1,500 ppm NaCl, 10.3 bar (150 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates may be up to 15% below shown values.

Operating limits

  • Maximum Operating Pressure:
    • 41 bar (600 psi) for fiberglassed elements
    • 20.7 bar (300 psi) for tape wrapped elements
  • Maximum Operating Temperature: 45 °C (113 °F)
  • Cleaning pH Range: 1.0 – 12.0
  • Chlorine Tolerance: < 0.1 ppm
  • Maximum Pressure Drop: 0.7 bar (10 psi) per element
  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Mechanical / Hydraulic

ModelElement Weight (kg (lb))Dim. A (mm (inches))Dim. B (mm (inches))Dim. C (mm (inches))Permeate Tube
Oltremare BR1HR-4611E5 (11)287.5 (11.32)116.8 (4.6)19.1 (0.75)Male
Oltremare LOW1– 4611E5 (11)287.5 (11.32)116.8 (4.6)19.1 (0.75)Male

For male elements, "C" is the outer diameter, and they have a protruding permeate tube.

Important Information

  • Start-up: Elements should be flushed for 30 minutes at low pressure, discarding permeate, prior to operation.
  • Cleaning: Periodic cleaning is required to ensure proper operation and prevent membrane damage. Refer to the Membrane Cleaning Guide.
  • Storage: Elements must be stored appropriately to ensure proper operation and prevent membrane damage. Refer to Element Storage Guides.

Disclaimer: This summary is based on the provided text extract. The original PDF may contain additional figures, footnotes, or revisions not present here. For contractual purposes, data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.