Datasheet summary
Foul1- 8040
Engineering summary from PDF text extraction for Foul1- 8040. Verify every value with the OEM datasheet.
Summary
Product identification
These are High rejection, low fouling brackish water RO elements, part of the Oltremare FOUL series. They are designed for difficult feedwaters, municipal wastewater, and other challenging feedwaters.
Membrane Characteristics
- Membrane: RO
- Membrane Type: Polyamide
- Stabilized Salt Rejection: 99.5%
- Minimum Salt Rejection: 99.0%
Design Information (Oltremare FOUL-8040 series)
| Model | Permeate Flow m³/day (gpd) | Maximum Feed Flow m³/h (gpm) | Membrane Area m² (ft²) | Feed Spacer Thickness (mil) |
|---|---|---|---|---|
| Oltremare FOUL1-8040 | 40 (10500) | 17 (75) | 37.2 (400) | 28 |
| Oltremare FOUL2G-8040 | 40 (10500) | 17 (75) | 37.2 (400) | 34 |
Test conditions for performance: 1,500 ppm NaCl, 15.5 bar (225 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown.
Operating limits
- Maximum Operating Pressure: 41 bar (600 psi)
- Maximum Operating Temperature: 45 °C (113 °F)
- Cleaning pH Range: 1.0 – 12.0
- Chlorine Tolerance: < 0.1 ppm
- Maximum Pressure Drop: 0.7 bar (10 psi) per element; 4 bar (60 psi) per housing
Feed water
- Maximum SDI₁₅: 5.0
- Maximum Turbidity: 1 NTU
Mechanical / hydraulic
Physical Dimensions (Oltremare FOUL-2540 and FOUL-4040 series)
| Model | Element Weight kg (lb) | Dim. A mm (inches) | Dim. B mm (inches) | Dim. C mm (inches) | Permeate Tube |
|---|---|---|---|---|---|
| Oltremare FOUL1-2540 | 16.4 (36) | 1016 (40) | 200 (7.89) | 28.6 (1.125) | Female |
| Oltremare FOUL1-4040 | 16.4 (36) | 1016 (40) | 200 (7.89) | 28.6 (1.125) | Female |
- For female elements, “C” is the inner diameter. For male elements, “C” is the outer diameter.
- Male elements have a protruding permeate tube, indicated as “D” in the diagram (not provided in this extract).
- Dimension “D” is 30.5 mm (1.2 in) for modules from 2514 to 4021. For 4040 module it is 26.7 mm (1.05 in).
Important Information
- Start-up: Flush elements for 30 minutes at low pressure and discard permeate prior to operation.
- Cleaning: Elements must be cleaned periodically to ensure proper operation and prevent membrane damage.
- Storage: Elements must be stored appropriately to ensure proper operation and prevent membrane damage.
Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, or more recent revisions. Contractual data for any project must always match the specific OEM PDF revision used on that project.
Official datasheet (PDF)