Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

Low 1 XL

Engineering summary from PDF text extraction for Low 1 XL. Verify every value with the OEM datasheet.

Summary

Product Identification

The Oltremare LOW1 XL series comprises extra area, low energy, high rejection brackish water reverse osmosis (RO) elements.

  • Membrane: RO
  • Membrane Type: Polyamide

Product Water

  • Stabilized Salt Rejection: 99.4% (for modules 4014XL and 4021XL) - 99.5% (for module 4040XL)
  • Minimum Salt Rejection: 98.0% (for modules 4014XL and 4021XL) – 99.2% (for module 4040XL)

Operating limits

  • Maximum Operating Pressure: 20.7 bar (300 psi)
  • Maximum Operating Temperature: 45 °C (113 °F)
  • Cleaning pH Range: 1.0 – 12.0
  • Chlorine Tolerance: < 0.1 ppm
  • Maximum Pressure Drop: 0.7 bar (10 psi) per element; 4 bar (60 psi) per housing
  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Mechanical / Hydraulic

The following table provides design information and physical dimensions for the Oltremare LOW1 XL series elements.

Product ModelPermeate Flow m³/day (gpd)Max Feed Flow m³/h (gpm)Membrane Area m² (ft²)Feed Spacer Thickness (mil)Element Weight kg (lb)Dim. A mm (inches)Dim. B mm (inches)Dim. C mm (inches)Permeate Tube
Oltremare LOW1 – 4014 - XL3.03 (800)2.72 (12)2.3 (25)281.4 (3)355.6 (14)100.3 (3.95)19.1 (0.75)Male
Oltremare LOW1 - 4021 – XL5.5 (1450)2.72 (12)4.2 (45)281.8 (4)533.4 (21)100.3 (3.95)19.1 (0.75)Male
Oltremare LOW1 - 4040 - XL12.5 (3300)3.6 (16)9.8 (105)283.6 (8)1016 (40)100.3 (3.95)19.1 (0.75)Male

Additional Physical Dimensions:

  • For male elements, Dimension "D" (protruding permeate tube) is:
    • 30.5 mm (1.2 in) for modules 4014-XL and 4021-XL
    • 26.7 mm (1.05 in) for module 4040-XL

Test Conditions for Permeate Flow Rating: The permeate flow values listed above are based on the following test conditions:

  • 1,500 ppm NaCl
  • 10.3 bar (150 psi) applied pressure
  • 25°C (77°F)
  • 15% recovery
  • pH 6.5 - 7
  • 30 minutes operation Flow rates will be no more than 15% below the values shown.

Important Notes:

  • Pretreatment is recommended for the removal of free chlorine and other oxidizing agents to prevent damage to membranes. Oxidizing agents, such as free chlorine, in contact with polyamide membranes may result in shortened operating life or membrane failure. Such oxidation damage is excluded from warranty.
  • Refer to the manufacturer's guides for detailed information on cleaning (TSG-C-001), operation (TSG-O-012), element start-up (TSG-O-005), and storage (TSG-O-009 & TSG-O-01).

Disclaimer

This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.