Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

MCE 1200 41 037 080

Engineering summary from PDF text extraction for MCE 1200 41 037 080. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product: ProCEM MCE 1200-41-037-080
  • Revision: 221014

Membrane Specifications

  • Membrane length: 1200 mm
  • Outer diameter MCE: 41 mm
  • Inner diameter channel: 3.8 mm
  • Pore size/MWCO: 80 nm
  • Number of channels: 37
  • Support material: Al₂O₃
  • Coating material: Al₂O₃
  • Membrane surface: 0.53 m²
  • Cross section area: 419.6 mm²
  • Weight: 2.9 kg
  • Clean water flux: 1900 LMH @ 25 °C

Housing and Sealing

  • Housing length: 1209 mm
  • Housing diameter: 168.3 mm
  • Housing material: 316 Ti
  • Number of membranes: 6
  • Total membrane surface: 3.18 m²
  • Total cross section area: 2517.74 mm²
  • Permeate connection: 2 x 1’’ Victaulic
  • Feed & retentate connection: 2 x 6’’ Victaulic
  • Weight: 32.5 kg
  • Membrane sealing diameter: Ø 41 x 3.5 mm
  • Membrane sealing material: EPDM, NBR, Viton, PTFE, Silicone

Operating Limits

  • Temperature: 5 -- 100 °C
  • pH: 0 -- 14
  • System pressure: 0 -- 10 bar
  • Transmembrane pressure: Max. 20 bar
  • Volume flow: 18 -- 55 m³/h
  • Cross flow velocity: 2 -- 6 m/s
  • Backwash pressure: Max. 5 bar
  • Backwash flow: 4 -- 10 m³/h
  • Cleaning agents: NaOCl, NaOH, citric acid
  • Cleaning frequency: Every 2 -- 4 weeks

Disclaimer: This summary is based solely on the provided text extract. The original OEM PDF may contain additional figures, footnotes, or revisions not present here. For contractual data and complete specifications, please refer to the specific OEM PDF revision used on your project. MANN+HUMMEL WFS reserves the right to change specifications without prior notification.