Datasheet summary
PureUltra ii PHF 107
Engineering summary from PDF text extraction for PureUltra ii PHF 107. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product: PureULTRA PHF-107-V UF
- Type: Pressure-Driven UF Modules
- Membrane Polymer: Polyvinylidene Fluoride (PVDF)
- Nominal Pore Size: 0.025 µm
- Membrane Type: Hollow Fiber
- Hollow Fiber Diameter OD / ID: 1.3 mm / 0.7 mm (0.051 inch / 0.028 inch)
- Nominal Membrane Area: 107 m² (1152 ft²)
- Housing Material: UPVC
- Membrane Potting: Epoxy / PU
- Filtration / Backwash Flow Path: Out → In / In → Out
- Operating Mode: Dead-End / Cross-Flow
- Preservative: Sodium meta-bisulphite
Operating Limits
- Filtrate Flow Range: 3.7 – 12.8 m³/h (16.3 – 56.5 gpm)
- Maximum Feed Pressure (at 20°C / 68°F): 6.4 bar (92.8 psi)
- Maximum Transmembrane Pressure: 2.3 bar (33.4 psi)
- Maximum Backflush Pressure: 2.7 bar (39.2 psi)
- Typical Air Scour Rate: 5 – 14 m³/h (3.0 – 7.1 SCFM)
- Maximum Air Scour Pressure: 1.2 bar (17.4 psi)
- pH Range for Operation: 2.0 – 11.0
- Temperature Range: 1 – 40°C (33.8 – 104°F)
Cleaning Parameters
- pH Range: 2.0 – 12.0
- Maximum Temperature: 40°C (104 °F)
- Maximum Active Chlorine Concentration: 3000 ppm
- Maximum Active Chlorine Exposure: >500,000 ppm·hours
- Cleaning Chemicals: Sodium Hypochlorite, caustic, hydrochloric acid / sulfuric acid / citric acid
Feed Water
PureULTRA modules feature Polyvinylidene Fluoride (PVDF) hollow fiber UF membrane that offers high chemical tolerance and physical robustness. The tight pore size helps in removal of solids, pathogens, and other suspended foulants. These modules can be used for a wide range of applications while treating feed waters from sea, surface, well, and secondary & tertiary wastewaters – both industrial and municipal.
Mechanical / Hydraulic
- Dry / Wet Weight: 62 kg (137 lb) / 127 kg (280 lb)
- Housing Diameter (D): 250 mm (9.8 in)
- Module Max. Installation Diameter (D2): 300 mm (11.8”)
- Module Diameter: 250 mm (9.8 in)
- Module Length: 2360 mm (92.9in)
- Feed / Reject Port: 2” Victaulic
- Permeate Port: 2” Victaulic
Important Information