Datasheet summary
PureUltra ii PHF 60
Engineering summary from PDF text extraction for PureUltra ii PHF 60. Verify every value with the OEM datasheet.
Summary
Product identification
The PureULTRA PHF-60-V UF module is a pressure-driven ultrafiltration module featuring a Polyvinylidene Fluoride (PVDF) hollow fiber membrane. The membrane's tight pore size enables the removal of solids, pathogens, and suspended foulants. It is designed for aggressive cleaning without loss of operating flux or hydrophilicity, suitable for treating a wide range of feed waters including sea, surface, well, and secondary & tertiary wastewaters.
- Model: PHF-60-V
- Membrane Polymer: Polyvinylidene Fluoride (PVDF)
- Nominal Pore Size: 0.025 µm
- Membrane Type: Hollow Fiber
- Hollow Fiber Diameter OD / ID: 1.3 mm / 0.7 mm (0.051 inch / 0.028 inch)
- Nominal Membrane Area: 60 m² (646 ft²)
- Housing Material: UPVC
- Membrane Potting: Epoxy / PU
- Filtration / Backwash Flow Path: Out → In / In → Out
- Operating Mode: Dead-End / Cross-Flow
- Preservative: Sodium meta-bisulphite
Operating limits
- Filtrate Flow Range: 2.1 – 6.0 m³/h (9.2 – 26.4 gpm)
- Maximum Feed Pressure (at 20°C / 68°F): 6.4 bar (92.8 psi)
- Maximum Transmembrane Pressure: 2.3 bar (33.4 psi)
- Maximum Backflush Pressure: 2.7 bar (39.2 psi)
- Typical Air Scour Rate: 5 – 14 m³/h (3.0 – 7.1 SCFM)
- Maximum Air Scour Pressure: 1.2 bar (17.4 psi)
- pH Range for Operation: 2.0 – 11.0
- Temperature Range: 1 – 40°C (33.8 – 104°F)
Cleaning parameters
- pH Range: 2.0 – 12.0
- Maximum Temperature: 40°C (104 °F)
- Maximum Active Chlorine Concentration: 3000 ppm
- Maximum Active Chlorine Exposure: >500,000 ppm·hours
- Cleaning Chemicals: Sodium Hypochlorite, caustic, hydrochloric acid / sulfuric acid / citric acid
Mechanical / hydraulic
- Dry / Wet Weight: 51 kg (112 lb) / 92 kg (202 lb)
- Housing Diameter (D) / Module max. Installation Diameter (D2): 250 mm (9.8 in) / 300mm (11.8”)
- Module Diameter: 250 mm (9.8 in)
- Module Length: 1507 mm (59.3 in)
- Feed / Reject Port: 2” Victaulic
- Permeate Port: 2” Victaulic
Important Information
For detailed procedures on storage, handling, installation, start-up, and cleaning, please refer to the PureULTRA Operation and Maintenance Manual and the PureULTRA Product Manual.
Disclaimer: This summary is based on the provided text extract. The original PDF may contain additional figures, footnotes, or revisions not present here. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.