Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

PureUltra ii PHF 80

Engineering summary from PDF text extraction for PureUltra ii PHF 80. Verify every value with the OEM datasheet.

Summary

The PureULTRA PHF-80-V UF module is a pressure-driven ultrafiltration module featuring a Polyvinylidene Fluoride (PVDF) hollow fiber membrane. This membrane offers high chemical tolerance and physical robustness with a tight pore size of 0.025 µm, which helps in the removal of solids, pathogens, and other suspended foulants. The unique PVDF polymer allows for aggressive cleaning without loss of operating flux or membrane hydrophilicity. PureULTRA UF modules are designed for consistent filtration efficiency and durability, suitable for treating a wide range of feed waters including sea, surface, well, and secondary & tertiary wastewaters (both industrial and municipal).

Product identification

  • Product Model: PHF-80-V
  • Membrane Polymer: Polyvinylidene Fluoride (PVDF)
  • Nominal Pore Size: 0.025 µm
  • Membrane Type: Hollow Fiber
  • Hollow Fiber Diameter OD / ID: 1.3 mm / 0.7 mm (0.051 inch / 0.028 inch)
  • Nominal Membrane Area: 80 m² (861 ft²)
  • Housing Material: UPVC
  • Membrane Potting: Epoxy / PU
  • Filtration / Backwash Flow Path: Out → In / In → Out
  • Operating Mode: Dead-End / Cross-Flow
  • Preservative: Sodium meta-bisulphite

Operating limits

  • Filtrate Flow Range: 2.8 – 8.8 m³/h (12.3 – 38.7 gpm)
  • Maximum Feed Pressure (at 20°C / 68°F): 6.4 bar (92.8 psi)
  • Maximum Transmembrane Pressure: 2.3 bar (33.4 psi)
  • Maximum Backflush Pressure: 2.7 bar (39.2 psi)
  • Typical Air Scour Rate: 5 – 14 m³/h (3.0 – 7.1 SCFM)
  • Maximum Air Scour Pressure: 1.2 bar (17.4 psi)
  • pH Range for Operation: 2.0 – 11.0
  • Temperature Range: 1 – 40°C (33.8 – 104°F)

Mechanical / hydraulic

  • Dry / Wet Weight: 54 kg (119 lb) / 106 kg (234 lb)
  • Housing Diameter (D): 250 mm (9.8 in)
  • Module Max. Installation Diameter (D2): 300 mm (11.8”)
  • Module Length: 1860 mm (73.2 in)
  • Feed / Reject Port: 2” Victaulic
  • Permeate Port: 2” Victaulic

Cleaning parameters

  • pH Range: 2.0 – 12.0
  • Maximum Temperature: 40°C (104 °F)
  • Maximum Active Chlorine Concentration: 3000 ppm
  • Maximum Active Chlorine Exposure: >500,000 ppm·hours
  • Cleaning Chemicals: Sodium Hypochlorite, caustic, hydrochloric acid / sulfuric acid / citric acid