Datasheet summary

TS 80 NF

Engineering summary from PDF text extraction for TS 80 NF. Verify every value with the OEM datasheet.

Summary

Product identification

  • Series: 8" X-20 Low Fouling RO Element Series
  • Core Tube: TriSep Style Core Tube
  • Model: 8040-X201-UWA
  • Membrane Type: X20 Fully Aromatic Polyamide-Urea Advanced Composite Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap with FoulGuard Technology

Operating limits

  • Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1

Feed water

  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 2 NTU
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm

Product water

  • Permeate flow: 10,400 GPD (39.0 m³/day)
    • Permeate flow is clean water flux at standard conditions. Not applicable for all feedwater conditions. Individual element's permeate flow may vary +/- 15%.
  • Average Salt Rejection: 98.50%
  • Minimum Salt Rejection: 99.50%
  • Performance Test Conditions: 2,000.0 ppm NaCl, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation.

Mechanical / hydraulic

  • Element Weight: 45 lbs (20 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Feed Spacer: 0.028" thick diamond spacer
  • Active Membrane Area: 400 ft² (37.2 m²)

Disclaimer: This summary is based solely on the extracted text provided. It may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.