Datasheet summary
Bio-Cel 2 Stack
Engineering summary from PDF text extraction for Bio-Cel 2 Stack. Verify every value with the OEM datasheet.
Summary
Product identification
- Series: 8" X-20 Low Fouling RO Element Series
- Model: 8040-X201-UWAN
- Membrane Type: X20 Fully Aromatic Polyamide-Urea Advanced Composite Membrane
- Configuration: Spiral Wound, Fiberglass Outer Wrap with FoulGuard Technology
- Active Membrane Area: 400 ft² (37.2 m²)
- Core Tube: TriSep Style
Operating limits
- Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
- Maximum Applied Pressure: 600 psi (41 bar)
- Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
- Feedwater pH Range: 2 - 11 continuous
- Chlorine Tolerance: <0.1 ppm
- Maximum Feed Flow: 80 GPM (18 m³/hr)
- Minimum Brine Flow/Permeate Flow Ratio: 5:1
- Maximum SDI (15 minutes): 5.0
- Maximum Turbidity: 2 NTU
Product water
Performance is based on the following test conditions: 2,000.0 ppm NaCl, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation. Permeate flow is clean water flux at standard conditions; individual element's permeate flow may vary +/- 15%.
- Permeate Flow (Model 8040-X201-UWAN): 10,400 GPD (39.0 m³/day)
- Average Salt Rejection: 99.50%
- Minimum Salt Rejection: 98.50%
Mechanical / hydraulic
- Element Weight: 45 lbs (20 kg)
- Length (A): 40.0 inches (1,016 mm)
- Diameter (B): 7.9 inches (200 mm)
- Permeate Tube (C): 1.50 inches (38.1 mm)
- Feed Spacer: 0.028" thick diamond spacer
Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.