Summary

Product identification

  • Series: 8" X-20 Low Fouling RO Element Series
  • Model: 8040-X201-UWAN
  • Membrane Type: X20 Fully Aromatic Polyamide-Urea Advanced Composite Membrane
  • Configuration: Spiral Wound, Fiberglass Outer Wrap with FoulGuard Technology
  • Active Membrane Area: 400 ft² (37.2 m²)
  • Core Tube: TriSep Style

Operating limits

  • Recommended Applied Pressure: 100 - 300 psi (7 - 21 bar)
  • Maximum Applied Pressure: 600 psi (41 bar)
  • Recommended Operating Temperature: 35 - 113°F (2 - 45°C)
  • Feedwater pH Range: 2 - 11 continuous
  • Chlorine Tolerance: <0.1 ppm
  • Maximum Feed Flow: 80 GPM (18 m³/hr)
  • Minimum Brine Flow/Permeate Flow Ratio: 5:1
  • Maximum SDI (15 minutes): 5.0
  • Maximum Turbidity: 2 NTU

Product water

Performance is based on the following test conditions: 2,000.0 ppm NaCl, 225.0 psi, 25°C, 15% recovery, pH 8.0, 30 minutes operation. Permeate flow is clean water flux at standard conditions; individual element's permeate flow may vary +/- 15%.

  • Permeate Flow (Model 8040-X201-UWAN): 10,400 GPD (39.0 m³/day)
  • Average Salt Rejection: 99.50%
  • Minimum Salt Rejection: 98.50%

Mechanical / hydraulic

  • Element Weight: 45 lbs (20 kg)
  • Length (A): 40.0 inches (1,016 mm)
  • Diameter (B): 7.9 inches (200 mm)
  • Permeate Tube (C): 1.50 inches (38.1 mm)
  • Feed Spacer: 0.028" thick diamond spacer