Summary

Product identification

The TRISEP® ACM2 series consists of high rejection brackish water reverse osmosis (RO) elements. The ACM2 membrane is described as MICRODYN-NADIR’s highest volume membrane, offering very high solute rejection and serving as a direct replacement for competitive RO products. These membranes are available in numerous strong and durable spiral-wound element designs.

Membrane Characteristics

  • Membrane Type: Polyamide
  • Stabilized Salt Rejection: 99.5%
  • Minimum Salt Rejection: 99.0%

Operating limits

  • Maximum Operating Pressure: 41 bar (600 psi)
  • Maximum Operating Temperature: 45°C (113°F)
  • Cleaning pH Range: 1.0 – 12.0
  • Chlorine Tolerance: < 0.1 ppm
  • Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing
  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Design Information

ModelPart NumberPermeate Flow m³/day (GPD)ᵃMembrane Area m² (ft²)Feed Spacer Thickness (mil)ᵇ
TRISEP® PLT 2540-ACM2-311640202512.5 (650)2.4 (26)31
TRISEP® PLT 4040-ACM2-311610404429.1 (2,400)7.9 (85)31
TRISEP® 4040-ACM2-TSA1640104419.3 (2,450)8.2 (88)31
TRISEP® 8040-ACM2-TSA16401084136.7 (9,700)33.9 (365)34
TRISEP® 8040-ACM2-UWA16402094140.5 (10,700)37.2 (400)28

ᵃ Test conditions: 2,000 ppm NaCl, 15.5 bar (225 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown. ᵇ All models on this sheet have fiberglass outer wrap and diamond-shaped feed spacers. All models include anti-telescoping devices (ATDs) attached to the ends of the element and one brine seal. All 4040 and 8040 models include one interconnector.

Physical Dimensions

ModelElement Weight kg (lb)ᶜDim. A mm (inches)Dim. B mm (inches)Dim. Cᵈ mm (inches)Permeate Tubeᵉ
TRISEP® PLT 2540-ACM2-313 (7)1,016 (40.0)64 (2.5)19.1 (0.75)Male
TRISEP® PLT 4040-ACM2-314 (9)1,016 (40.0)99 (3.9)19.1 (0.75)Male
TRISEP® 4040-ACM2-TSA4 (9)1,016 (40.0)99 (3.9)19.1 (0.75)Female
TRISEP® 8040-ACM2-TSA16 (36)1,016 (40.0)201 (7.9)38.1 (1.50)Female
TRISEP® 8040-ACM2-UWA16 (36)1,016 (40.0)201 (7.9)38.1 (1.50)Female

ᶜ Shipping weight is dependent on packaging material and quantity shipped. ᵈ Diameters for Dimension “C” are as follows. For Female elements, “C” is the Inner Diameter. For Male elements, “C” is the Outer Diameter. ᵉ Male elements have a protruding permeate tube, indicated as “D” in the diagram. Dimension “D” is 25.4 mm (1.0 in).

Important Operating Information

  • Start-up: MANN+HUMMEL Water & Fluid Solutions recommends flushing elements for 30 minutes at low pressure and discarding permeate during the flush prior to operation.
  • Cleaning: TRISEP® membrane elements must be cleaned periodically to ensure proper operation and to prevent membrane damage.
  • Storage: TRISEP membrane elements must be stored appropriately to ensure proper operation and to prevent membrane damage.