Datasheet summary
ACM 3
Engineering summary from PDF text extraction for ACM 3. Verify every value with the OEM datasheet.
Summary
Product Identification
The TRISEP® ACM series consists of low energy brackish water RO elements, offering high solute rejection at moderately lower pressure. These are strong and durable spiral-wound elements.
- Model: TRISEP® 8040-ACM3-TSA
- Part Number: 164030841
- Membrane Type: Polyamide
- Membrane Designation: ACM3
- Feed Spacer Thickness: 34 mil
- This model features a fiberglass outer wrap, diamond-shaped feed spacers, anti-telescoping devices (ATDs) attached to the element ends, one brine seal, and one interconnector.
Performance Data
- Permeate Flow: 41.6 m³/day (11,000 GPD)
- Membrane Area: 33.9 m² (365 ft²)
- Stabilized Salt Rejection: 99.3%
- Minimum Salt Rejection: 98.8%
Test Conditions: Performance data is based on 2,000 ppm NaCl, 15.5 bar (225 psi) operating pressure, 25°C (77°F) temperature, 15% recovery, and pH 8.0 after 30 minutes of operation. Flow rates may be up to 15% below the stated values.
Operating Limits
- Maximum Operating Pressure: 41 bar (600 psi)
- Maximum Operating Temperature: 45°C (113°F)
- Cleaning pH Range: 1.0 – 12.0
- Chlorine Tolerance: < 0.1 ppm
- Note: Pretreatment is recommended for the removal of free chlorine and other oxidizing agents to prevent damage. Oxidation damage is excluded from warranty.
- Maximum Pressure Drop:
- 1 bar (15 psi) per element
- 4 bar (60 psi) per housing
- Maximum SDI₁₅: 5.0
- Maximum Turbidity: 1 NTU
Mechanical / Hydraulic
- Permeate Tube Type: Female
- Model: TRISEP® 8040-ACM3-TSA
- Element Weight: 16 kg (36 lb)
- Dim. A (Length): 1,016 mm (40.0 inches)
- Dim. B (Diameter): 201 mm (7.9 inches)
- Dim. C (Inner Diameter): 38.1 mm (1.50 inches)
Important Information
- Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate during the flush prior to operation.
- Cleaning: Elements require periodic cleaning to maintain proper operation and prevent damage.
- Storage: Elements must be stored appropriately to ensure proper operation and prevent damage.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.