The TRISEP® ACM4 series consists of Low Energy Brackish Water RO Elements. These polyamide spiral-wound membranes are designed for versatile use in a wide variety of water purification and process applications, offering high solute rejection at moderately lower pressure.
- Membrane Type: Polyamide
- Stabilized Salt Rejection: 99.3%
- Minimum Salt Rejection: 98.8%
Operating limits
- Maximum Operating Pressure: 41 bar (600 psi)
- Maximum Operating Temperature: 45°C (113°F)
- Cleaning pH Range: 1.0 – 12.0
- Chlorine Tolerance: < 0.1 ppm (Pretreatment is recommended for the removal of free chlorine and other oxidizing agents to prevent damage to membranes.)
- Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing
- Maximum SDI₁₅: 5.0
- Maximum Turbidity: 1 NTU
Mechanical / hydraulic
Design Information
The following models feature a fiberglass outer wrap and diamond-shaped feed spacers. All models include anti-telescoping devices (ATDs) attached to the ends of the element and one brine seal. All 4040 and 8040 models include one interconnector.
Performance is based on test conditions: 2,000 ppm NaCl, 15.5 bar (225 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown.
- TRISEP® PLT 2540-ACM4-31
- Part Number: 164040251
- Permeate Flow: 3.8 m³/day (1,000 GPD)
- Membrane Area: 2.4 m² (26 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® PLT 4040-ACM4-31
- Part Number: 161050442
- Permeate Flow: 12.7 m³/day (3,350 GPD)
- Membrane Area: 7.9 m² (85 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® 4040-ACM4-TSA
- Part Number: 164040441
- Permeate Flow: 13.1 m³/day (3,450 GPD)
- Membrane Area: 8.2 m² (88 ft²)
- Feed Spacer Thickness: 31 mil
- TRISEP® 8040-ACM4-TSA
- Part Number: 164040841
- Permeate Flow: 55.3 m³/day (14,600 GPD)
- Membrane Area: 33.9 m² (365 ft²)
- Feed Spacer Thickness: 34 mil
- TRISEP® 8040-ACM4-UWA
- Part Number: 164040941
- Permeate Flow: 60.6 m³/day (16,000 GPD)
- Membrane Area: 37.2 m² (400 ft²)
- Feed Spacer Thickness: 28 mil
Physical Dimensions
For Female elements, "Dim. C" is the Inner Diameter. For Male elements, "Dim. C" is the Outer Diameter, and they also have a protruding permeate tube ("D") of 25.4 mm (1.0 in).
- TRISEP® PLT 2540-ACM4-31
- Element Weight: 3 kg (7 lb)
- Dim. A: 1,016 mm (40.0 inches)
- Dim. B: 64 mm (2.5 inches)
- Dim. C: 19.1 mm (0.75 inches)
- Permeate Tube: Male
- TRISEP® PLT 4040-ACM4-31
- Element Weight: 4 kg (9 lb)
- Dim. A: 1,016 mm (40.0 inches)
- Dim. B: 99 mm (3.9 inches)
- Dim. C: 19.1 mm (0.75 inches)
- Permeate Tube: Male
- TRISEP® 4040-ACM4-TSA
- Element Weight: 4 kg (9 lb)
- Dim. A: 1,016 mm (40.0 inches)
- Dim. B: 99 mm (3.9 inches)
- Dim. C: 19.1 mm (0.75 inches)
- Permeate Tube: Female
- TRISEP® 8040-ACM4-TSA
- Element Weight: 16 kg (36 lb)
- Dim. A: 1,016 mm (40.0 inches)
- Dim. B: 201 mm (7.9 inches)
- Dim. C: 38.1 mm (1.50 inches)
- Permeate Tube: Female
- TRISEP® 8040-ACM4-UWA
- Element Weight: 16 kg (36 lb)
- Dim. A: 1,016 mm (40.0 inches)
- Dim. B: 201 mm (7.9 inches)
- Dim. C: 38.1 mm (1.50 inches)
- Permeate Tube: Female
Important Information
- Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate during the flush prior to operation. For a detailed procedure, refer to the Element Start-Up Guide – System Start-Up (TSG-O-005).
- Cleaning: TRISEP® membrane elements must be cleaned periodically for proper operation and to prevent membrane damage. Consult the Membrane Cleaning Guide – Water Application Elements (TSG-C-001).
- Storage: Proper storage is essential for TRISEP membrane elements to ensure proper operation and to prevent membrane damage. Refer to Element Storage Guides (TSG-O-009 & TSG-O-010).