Summary

Product identification

The TRISEP® DS Food & Dairy MV020 Series consists of TRISEP® sanitary membrane elements designed for food and dairy applications. These elements utilize NADIR® MV020 polyvinylidene fluoride (PVDF) microfiltration membranes with a nominal pore size of 0.20 µm.

The elements are built with FDA compliant materials, comply with European food regulations (EU 10/2011 and EC 1935/2004), and meet USDA standards, specifically USDA 3A sanitary standard 45-03. They also hold Halal and Kosher certifications.

All models detailed on this sheet feature a netting outer wrap and diamond-shaped feed spacers.

Membrane Characteristics

  • Membrane: NADIR® MV020
  • Membrane Type: Polyvinylidene Fluoride (PVDF)
  • Nominal Pore Size: 0.2 µm

Design Information

ModelMembrane Area m² (ft²)Feed Spacer Thickness (mil)
TRISEP® DS MV020 3838-465.7 (61)46
TRISEP® DS MV020 6338-3120.5 (221)31
TRISEP® DS MV020 6338-4617.1 (184)46
TRISEP® DS MV020 8038-4625.0 (269)46

Operating limits

  • Maximum Operating Pressure: 10 bar (145 psi)
  • Maximum Operating Temperature: 50°C (122°F)
  • Cleaning pH/Temperature Range: 1.5 – 11.5 at 50°C (122°F)
  • Cleaning Chlorine Tolerance: 200 ppm for sanitization at pH ≥ 10.5
  • Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing

Mechanical / hydraulic

ModelElement Weight kg (lb)Dim. A mm (inches)Dim. B mm (inches)Dim. C (Inner Diameter) mm (inches)Permeate Tube
TRISEP® DS MV020 3838-464 (9)965 (38.0)96 (3.8)21.1 (0.83)Female
TRISEP® DS MV020 6338-3111 (24)965 (38.0)162 (6.3)28.9 (1.138)Female
TRISEP® DS MV020 6338-4611 (24)965 (38.0)162 (6.3)28.9 (1.138)Female
TRISEP® DS MV020 8038-4616 (36)965 (38.0)201 (7.9)28.9 (1.138)Female

Important Information

  • Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate during the flush prior to operation.
  • Cleaning: TRISEP® membrane elements require periodic cleaning to maintain proper operation and prevent membrane damage.
  • Storage: Elements must be stored appropriately to ensure proper operation and prevent damage.

Customizable Specialty Elements

Custom membrane and element designs are available for challenging water and process applications, including low-fouling RO, submerged UF, continuous high temperature, ultra-high pressure, and unique sanitary designs.