Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

DS UH 030

Engineering summary from PDF text extraction for DS UH 030. Verify every value with the OEM datasheet.

Summary

Product identification

These TRISEP® DS Food & Dairy UH030 Series sanitary membrane elements are designed for food and dairy applications. They feature a NADIR® UH030 hydrophilic polyethersulfone (PESH) membrane with a nominal 30,000 Da molecular weight cut-off (M.W.C.O.).

The elements are compliant with:

  • FDA (CFR Title 21) compliant materials
  • European food regulations (EU 10/2011 and EC 1935/2004)
  • USDA standards and USDA 3A sanitary standard 45-03
  • Halal and Kosher certifications

All models on this datasheet have a netting outer wrap and diamond-shaped feed spacers.

Operating limits

  • Maximum Operating Pressure: 10 bar (145 psi)
  • Maximum Operating Temperature: 50°C (122°F)
  • Cleaning pH/Temperature Range: 1.5 – 11.5 at 50°C (122°F)
  • Cleaning Chlorine Tolerance: 200 ppm for sanitization at pH ≥ 10.5
  • Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing

Mechanical / hydraulic

Membrane Characteristics

  • Membrane: NADIR® UH030
  • Membrane Type: Polyethersulfone (PES)
  • Nominal M.W.C.O. (Da): 30,000

Design Information

ModelMembrane Area m² (ft²)Feed Spacer Thickness (mil)
TRISEP® DS UH030 3838-317.0 (75)31
TRISEP® DS UH030 3838-465.7 (61)46
TRISEP® DS UH030 3838-804.0 (43)80
TRISEP® DS UH030 4333-317.6 (82)31
TRISEP® DS UH030 4333-466.3 (68)46
TRISEP® DS UH030 4333-804.3 (46)80
TRISEP® DS UH030 6338-3120.5 (221)31
TRISEP® DS UH030 6338-4617.1 (184)46
TRISEP® DS UH030 6338-8011.5 (124)80
TRISEP® DS UH030 8338-3134.0 (366)31
TRISEP® DS UH030 8338-4627.5 (296)46
TRISEP® DS UH030 8338-8021.2 (228)80

Physical Dimensions

Dimension "C" is the Inner Diameter. Shipping weight is dependent on packaging material and quantity shipped.

ModelElement Weight kg (lb)Dim. A mm (inches)Dim. B mm (inches)Dim. C mm (inches)Permeate Tube
TRISEP® DS UH030 3838-314 (9)965 (38.0)96 (3.8)21.1 (0.83)Female
TRISEP® DS UH030 3838-464 (9)965 (38.0)96 (3.8)21.1 (0.83)Female
TRISEP® DS UH030 3838-804 (9)965 (38.0)96 (3.8)21.1 (0.83)Female
TRISEP® DS UH030 4333-314 (9)838 (33.0)109.5 (4.3)21.1 (0.83)Female
TRISEP® DS UH030 4333-464 (9)838 (33.0)109.5 (4.3)21.1 (0.83)Female
TRISEP® DS UH030 4333-804 (9)838 (33.0)109.5 (4.3)21.1 (0.83)Female
TRISEP® DS UH030 6338-3111 (24)965 (38.0)162 (6.3)28.9 (1.138)Female
TRISEP® DS UH030 6338-4611 (24)965 (38.0)162 (6.3)28.9 (1.138)Female
TRISEP® DS UH030 6338-8011 (24)965 (38.0)162 (6.3)28.9 (1.138)Female
TRISEP® DS UH030 8338-3118 (40)965 (38.0)211 (8.3)28.9 (1.138)Female
TRISEP® DS UH030 8338-4618 (40)965 (38.0)211 (8.3)28.9 (1.138)Female
TRISEP® DS UH030 8338-8018 (40)965 (38.0)211 (8.3)28.9 (1.138)Female

General Recommendations

  • Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate prior to operation. Refer to the Element Start-Up Guide – System Start-Up (TSG-O-005) for more detailed procedures.
  • Cleaning: TRISEP® membrane elements require periodic cleaning to ensure proper operation and prevent membrane damage. Consult the Membrane Cleaning Guide – Food & Dairy: UF & MF Elements (TSG-C-004).
  • Storage: Elements must be stored appropriately to ensure proper operation and prevent membrane damage. Refer to Element Storage Guides (TSG-O-009 & TSG-O-010).

Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.