UE50 PES

Engineering summary from PDF text extraction for UE50 PES. Verify every value with the OEM datasheet.

Summary

Product identification

TRISEP® UE50 PES Ultrafiltration Elements are polyethersulfone (PES) ultrafiltration membranes with a nominal molecular weight cut-off (M.W.C.O.) of 100,000 Daltons. They are designed for the removal of macromolecules or concentration of large organic solutes in both water and process applications. UE50 membranes are available in various spiral designs that can be customized.

Operating limits

  • Maximum Operating Pressure: 21 bar (300 psi)
  • Maximum Operating Temperature: 45°C (113°F)
  • Cleaning pH Range: 1.0 – 12.0
  • Cleaning Chlorine Tolerance: 200 ppm (sanitization) at pH ≥ 10.5
  • Maximum Pressure Drop: 1 bar (15 psi) per element; 4 bar (60 psi) per housing

Feed water

  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Product water

Permeate flow rates are measured under specific test conditions: Clean water, 2.1 bar (30 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown.

Mechanical / hydraulic

Design Information

ModelPermeate Flow m³/day (GPD)Membrane Area m² (ft²)Feed Spacer Thickness (mil)
TRISEP® PLT 2540-UE50-314.5 (1,200)2.4 (26)31
TRISEP® PLT 2540-UE50-4615.1 (4,000)1.5 (16)46
TRISEP® PLT 4040-UE50-3116.7 (4,400)7.4 (80)31
TRISEP® PLT 4040-UE50-4612.9 (3,400)5.8 (62)46
TRISEP® 4040-UE50-QXA13.2 (3,500)6.0 (65)47
TRISEP® 8040-UE50-QXA56.8 (15,000)25.1 (270)47
TRISEP® 8040-UE50-QSA75.7 (20,000)33.0 (355)31
TRISEP® 8040-UE50-QSFA75.7 (20,000)33.0 (355)31

All models on this sheet have fiberglass outer wrap. All 47 mil feed spacers are parallel; all other models have diamond-shaped feed spacers. All models include anti-telescoping devices (ATDs) attached to the ends of the element and one brine seal. All 4040 and 8040 models include one interconnector.

Physical Dimensions

ModelElement Weight kg (lb)Dim. A mm (inches)Dim. B mm (inches)Dim. C mm (inches)Permeate Tube
TRISEP® PLT 2540-UE50-313 (7)1,016 (40.0)64 (2.5)19.1 (0.75)Male
TRISEP® PLT 2540-UE50-463 (7)1,016 (40.0)64 (2.5)19.1 (0.75)Male
TRISEP® PLT 4040-UE50-314 (9)1,016 (40.0)99 (3.9)19.1 (0.75)Male
TRISEP® PLT 4040-UE50-464 (9)1,016 (40.0)99 (3.9)19.1 (0.75)Male
TRISEP® 4040-UE50-QXA4 (9)1,016 (40.0)99 (3.9)19.1 (0.75)Female
TRISEP® 8040-UE50-QXA16 (36)1,016 (40.0)201 (7.9)38.1 (1.50)Female
TRISEP® 8040-UE50-QSA16 (36)1,016 (40.0)201 (7.9)38.1 (1.50)Female
TRISEP® 8040-UE50-QSFA16 (36)1,016 (40.0)201 (7.9)28.6 (1.125)Female

Note: Shipping weight is dependent on packaging material and quantity shipped. For Female elements, Dimension “C” is the Inner Diameter. For Male elements, “C” is the Outer Diameter. Male elements have a protruding permeate tube, with a dimension of 25.4 mm (1.0 in).

Important Information

  • Start-up: MANN+HUMMEL Water & Fluid Solutions recommends flushing elements for 30 minutes at low pressure and discarding permeate during the flush prior to operation.
  • Cleaning: TRISEP® membrane elements must be cleaned periodically to ensure proper operation and to prevent membrane damage.
  • Storage: TRISEP membrane elements must be stored appropriately to ensure proper operation and to prevent membrane damage.