Back to Mann + Hummel
MANN+HUMMEL logo

Datasheet summary

UF10 PES

Engineering summary from PDF text extraction for UF10 PES. Verify every value with the OEM datasheet.

Summary

Product identification

The TRISEP® UF10 is a polyethersulfone (PES) ultrafiltration membrane element with a nominal molecular weight cut-off (M.W.C.O.) of 10,000 Daltons. These elements are designed for various applications, including food and dairy process applications, water purification for dialysis, and general industrial water purification.

Membrane Characteristics

  • Membrane Type: Polyethersulfone (PES)
  • Nominal M.W.C.O.: 10,000 Da

Design Information

The elements are available in several spiral-wound designs, all featuring a 31 mil feed spacer thickness, fiberglass outer wrap, and diamond-shaped feed spacers. All models include anti-telescoping devices (ATDs) and one brine seal. The 4040 and 8040 models also include one interconnector.

ModelPermeate Flow m³/day (GPD)Membrane Area m² (ft²)Feed Spacer Thickness (mil)
TRISEP® PLT 2540-UF10-311.9 (500)2.4 (26)31
TRISEP® PLT 4040-UF10-3111.4 (3,000)7.4 (80)31
TRISEP® 8040-UF10-QSA75.7 (20,000)33.0 (355)31
TRISEP® 8040-UF10-QSFA75.7 (20,000)33.0 (355)31

Test conditions for permeate flow: Clean water, 2.1 bar (30 psi), 25°C (77°F), 15% recovery, pH 8.0, 30 minutes operation. Flow rates will be no more than 15% below the values shown.

Operating limits

  • Maximum Operating Pressure: 21 bar (300 psi)
  • Maximum Operating Temperature: 45°C (113°F)
  • Cleaning pH Range: 1.0 – 12.0
  • Cleaning Chlorine Tolerance: 200 ppm (sanitization) at pH ≥ 10.5
  • Maximum Pressure Drop:
    • 1 bar (15 psi) per element
    • 4 bar (60 psi) per housing
  • Maximum SDI₁₅: 5.0
  • Maximum Turbidity: 1 NTU

Mechanical / hydraulic

Physical Dimensions

ModelElement Weight kg (lb)Dim. A mm (inches)Dim. B mm (inches)Dim. C mm (inches)Permeate Tube
TRISEP® PLT 2540-UF10-313 (7)1,016 (40.0)64 (2.5)19.1 (0.75)Male
TRISEP® PLT 4040-UF10-314 (9)1,016 (40.0)99 (3.9)19.1 (0.75)Male
TRISEP® 8040-UF10-QSA16 (36)1,016 (40.0)201 (7.9)38.1 (1.50)Female
TRISEP® 8040-UF10-QSFA16 (36)1,016 (40.0)201 (7.9)28.6 (1.125)Female

Notes:

  • Shipping weight is dependent on packaging material and quantity shipped.
  • For Female elements, Dimension “C” is the Inner Diameter. For Male elements, “C” is the Outer Diameter.
  • Male elements have a protruding permeate tube, Dimension “D”, which is 25.4 mm (1.0 in).

Important Information

  • Start-up: It is recommended to flush elements for 30 minutes at low pressure and discard permeate during the flush prior to operation. Refer to the Element Start-Up Guide – System Start-Up (TSG-O-005) for more detailed procedures.
  • Cleaning: TRISEP® membrane elements require periodic cleaning to ensure proper operation and prevent membrane damage. Refer to the Membrane Cleaning Guide – Water Application Elements (TSG-C-001).
  • Storage: TRISEP® membrane elements must be stored appropriately. Refer to Element Storage Guides (TSG-O-009 & TSG-O-010).

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual purposes, please refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.